Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Language: EN

Blauberg Freshbox 100 ERV WiFi


Single-room air handling units. Maximum air flow up to 100 m³/h.
EAN codeEAN4058448050510
  • Description
  • Characteristics
  • Downloads
  • Accessories
  • Additional characteristics
  • Designation key
  • Dimensions
Description
Description
FEATURES  

Efficient solution for supply and exhaust ventilation of enclosed spaces.Electric preheater or reheater modification available for cold climate conditions.Heat exchanger with an enthalpy membrane modification available for humid and hot climate conditions.Low-energy EC motors.Silent operation.

Upgradeable with an exhaust duct to provide air extraction from the bathroom.Easy installation.Compact size.Controlled by Android or iOS smartphone or tablet over Wi-Fi.

DESIGN  MOTORS

Polymer coated metal casing decorated with an acrylic front panel. Heat and noise insulation is ensured by a layer of 10 mm cellular synthetic rubber.The front panel provides convenient access for filter maintenance and has a lock for extra security.The unit has two ∅ 100 mm pipes for fresh air intake and stale air extraction outside. The third ∅ 100 mm pipe (included in the scope of delivery) can be additionally fitted to the unit to connect the exhaust air duct from the bathroom.

The units feature efficient electronically commutated (EC) motors with an external rotor and impellers with forward curved blades. These stateof- the-art motors are the most advanced solution in energy efficiency today.
EC motors are characterised with high performance and optimum control across the entire speed range. In addition to that the efficiency of electronically commutated motors reaches very impressive levels of up to 90 %.

AIR DAMPERS HEAT AND ENERGY RECOVERY

The unit is equipped with supply and exhaust air dampers which activate automatically to prevent drafts while the unit is off.

AIR FILTRATION

Freshbox 100 WiFi, Freshbox E-100 WiFi: supply air cleaning is provided by the G4 and F8 filters. To meet more stringent air purity requirements the F8 filter can be replaced with an H13 or F8 carbon filter (purchased separately). Exhaust air is cleaned by the filter G4.Freshbox E1-100 WiFi, Freshbox E2-100 WiFi: the built-in G4 supply filter and G4 extract filter provide air filtration.

OPERATING PRINCIPLE

The cold outdoor air passes through the filters and the heat exchanger and then is delivered to the serviced space by the supply centrifugal fan.
Warm stale air from indoors passes through the filter and the heat exchanger and is discharged outdoors by the centrifugal fan.
The supply and exhaust air flows are fully separated which helps eliminate the possibility of odour or microbial transfer between the streams.

The Freshbox 100 WiFi units are equipped with a counter-flow heat recovery core with a polystyrene core.

  • In the cold season the exhaust air heat is captured and transferred to the supply air stream which reduces the ventilation-generated heat losses. Some condensate may form during heat recovery. The condensate is collected in the drain pan and is removed from the exhaust air duct.
  • In the warm season the intake air heat is transferred to the extract air stream. This allows for a considerable reduction of the supply air temperature which, in turn, reduces the air conditioning load.

The Freshbox 100 ERV WiFi units are equipped with a counter-flow energy recovery core with an enthalpy membrane at the core.

  • In the cold season the exhaust air heat and moisture are transferred to the supply air stream through the enthalpy membrane reducing the heat losses through ventilation.
  • In the warm season the heat and humidity of the outdoor air is absorbed by extract air flow through the enthalpy membrane. This way the supply air temperature and humidity decreases and heat recovery reduces operation loads for the air conditioner.

HEATERS

PREHEATING

Freshbox E-100 WiFi, Freshbox E2-100 WiFi units are equipped with an electric preheater for freeze protection of the heat exchanger.

REHEATING

Freshbox E1-100 WiFi, Freshbox E2-100 WiFi units feature an electric reheater to raise the supply air temperature as necessary.

FREEZE PROTECTION

Freshbox 100 WiFi features an exhaust air temperature sensor downstream of the heat exchanger which disables the supply fan to let the warm extract air warm up the heat exchanger. After that the supply fan is turned on and the unit reverts to the normal operation mode.
Overheating protection for Freshbox E-100 WiFi and Freshbox E2-100 WiFi is implemented with a preheater.

CONTROL  

The unit is equipped with a control panel.The remote control is supplied as standardWi-Fi communication.

AUTOMATIC FUNCTIONS

  Freshbox 100 WiFi
Freshbox E-100 WiFi
Freshbox E1-100 WiFi
Freshbox E2-100 WiFi
Speed selection
Filter replacement indication
Alarm indication
Speed setup
Timer
Week scheduler
Reheater enabled/disabled  
Supply air temperature setup  
Control with the mobile application Android / iOS

Download
Andrioid application
Blauberg Freshbox
Download
iOS application
Blauberg Freshbox

REMOTE CONTROL

1. Turning unit on/off
2. Speed selection (Min/Mid/Max)
3. Increasing temperature set point for the reheater (available for the models with a reheater)
4. Turning reheater on/off (available for the models with a reheater)
5. Decreasing temperature set point for the reheater (available for the models with a reheater)
6. Turning timer on/off
7. Activation/deactivation of the scheduled operation mode

CONTROL PANEL

MOUNTING EXAMPLE  

Each space requiring ventilation is equipped with one or several Freshbox 100 WiFi units.
A single unit is capable to ensure efficient ventilation in spaces with floor area up to 75 m2.

Freshbox 100 WiFi units can be upgraded with a bathroom exhaust air duct. To enable such a configuration the units can be additionally equipped with the optional ø 100 mm spigot (supplied as standard).

FRESHBOX 100 WIFI DEPLOYMENT IN A COMPACT RESIDENTIAL SPACE
FRESHBOX 100 WIFI MOUNTING EXAMPLE IN THE OFFICE
Characteristics
Characteristics
Parameter Freshbox 100 ERV WiFi
Speed V
Freshbox 100 ERV WiFi
Speed I
Freshbox 100 ERV WiFi
Speed II
Freshbox 100 ERV WiFi
Speed III
Freshbox 100 ERV WiFi
Speed IV
Measurement unit
Speed V I II III IV -
Voltage 110-240 110-240 110-240 110-240 110-240 V
Phase 1 1 1 1 1 ˜
Frequency 50/60 50/60 50/60 50/60 50/60 Hz
Reheater power consumption - - - - - W
Max. power without electric heater 53 20 23 29 37 W
Max. unit current with electric heater - - - - - A
Max. unit current without electric heater 0.4 0.4 0.4 0.4 0.4 A
Preheater power consumption - - - - - W
RPM 2200 2200 2200 2200 2200 min-1
Maximum air flow 100 30 44 60 75 m³/h
Maximum air flow 28 8 12 17 21 l/s
Sound pressure level at 3 m in accordance with ISO 3741:2004 39 13 20 27 33 dBА
Transported air temperature -15...+40 -15...+40 -15...+40 -15...+40 -15...+40 °С
Extract filter G4 G4 G4 G4 G4 -
Insulation thikness 10 10 10 10 10 mm
Heat recovery efficiency 83 96 94 89 85 %
Heat exchanger type counter-flow counter-flow counter-flow counter-flow counter-flow -
Remote control panel Sensor Wi-Fi Sensor Wi-Fi Sensor Wi-Fi Sensor Wi-Fi Sensor Wi-Fi -
Functions Wi-Fi, Filter replacement indication, Timer, Weekly schedule Wi-Fi, Filter replacement indication, Timer, Weekly schedule Wi-Fi, Filter replacement indication, Timer, Weekly schedule Wi-Fi, Filter replacement indication, Timer, Weekly schedule Wi-Fi, Filter replacement indication, Timer, Weekly schedule -
Heat exchanger material enthalpy enthalpy enthalpy enthalpy enthalpy -
Connected air duct diameter 100 100 100 100 100 mm
Weight 31 31 31 31 31 kg
Heating without heating without heating without heating without heating without heating -
Casing material polymer-coated steel polymer-coated steel polymer-coated steel polymer-coated steel polymer-coated steel -
SEC class A A A A A -
* Heat recovery efficiency is specified in compliance with EN 13141-8 Heat recovery efficiency is specified in compliance with EN 13141-8 Heat recovery efficiency is specified in compliance with EN 13141-8 Heat recovery efficiency is specified in compliance with EN 13141-8 Heat recovery efficiency is specified in compliance with EN 13141-8 -
** -
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
Freshbox 100 WiFi - data sheet (pdf 1.65Mb)
Freshbox 100 WiFi - image (png 408.21Kb)
EH Freshbox - data sheet (pdf 177.53Kb)
Freshbox 100 WiFi - user's manual (pdf 3.85Mb)
Freshbox 100 WiFi - Connection to a "Smart Home" system (pdf 851.33Kb)
Freshbox 100 ERV WiFi - Energy Label (pdf 56.48Kb)
Freshbox 100 ERV WiFi - Specification (pdf 34.73Kb)
Filters maintenance manual (pdf 3.04Mb)
Accessories
Accessories
Name Description
MS Freshbox 100 chrome

Mounting kit:

  • Two Ø 100 mm air ducts, 500 mm long
  • Ventilation outer hood made of polished steel
  • Cardboard template
MS Freshbox 100 white

Mounting kit:

  • Two Ø 100 mm air ducts, 500 mm long
  • Ventilation outer hood, painted white
  • Cardboard templateн
AH Freshbox 100 chrome Ventilation outer hood made of polished steel
AH Freshbox 100 white Ventilation outer hood, painted white
EH Freshbox 100 Heater to prevent condensate freezing in the drain pipe and outer ventilation hood
FP 193x158x18 G4 PPI G4 Panel filter
FP 193x158x47 F8 F8 Panel filter
FP 193x158x47 F8 C F8 Carbon panel filter
FP 193x158x47 H13 H13 Hepa panel filter
HR-S Humidity sensor
CD-1 CO2 sensor with LED CO2 indication and a sensor button for operation mode selection
CD-2 CO2 Sensor
Additional characteristics
Additional characteristics

Sound-power level, A - weighted Total Octave frequency band [Hz] Sound pressure level at 3 m, A-filter applied Sound pressure level at 1 m, A-filter applied
63 125 250 500 1000 2000 4000 8000
LwA to environment [dBA] 49 45 40 44 38 33 29 27 22 28 38
Designation key
Designation key
Model Heater   Rated air flow [m³/h] Heat exchanger core type Control
Freshbox

_: no heater
Е: preheating
Е1: reheating
Е2: preheating and reheating

- 100 _: heat recovery 
ERV: energy recovery
WiFi: sensor control panel and Wi-Fi communication
Dimensions
Dimensions