Blauberg KOMFORT L



- Description
- Modifications
- Downloads
- Designation key
- Accessories
FEATURES
Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. Heat recovery minimises ventilation heat losses. Control of air exchange for creating comfortable indoor microclimate. Compatible with round Ø 125 to 315 mm air ducts. DESIGNThe casing is made of aluminium profile and double-skinned aluzinc panels, internally filled with mineral wool layer for heat and sound insulation. The casing has fixing brackets with vibration absorbing connectors for easy installation. The spigots for connection to the air ducts are located at the side of the unit and are rubber sealed for airtight connection to the air ducts. The hinged casing side panels ensure easy access to the internals for cleaning, filter replacement and other maintenance operations. |
Asynchronous external rotor motors and centrifugal double-intake impellers with forward curved blades are used for air supply and exhaust. Integrated motor overheating protection with automatic restart. Dynamically balanced impellers. Equipped with ball bearings for longer service life. Reliable and quiet operation. |
|
KOMFORT L 350/500/530/600 | ||
|
||
KOMFORT L 1200/2200 | ||
|
||
HEAT RECOVERY
The integrated automatic freeze protection is used to prevent freezing of the heat exchanger in the cold season. The supply fan turns off according to the temperature sensor to get the heat exchanger warmed up with extract air. After that the supply fan turns on and the unit continues to run in the standard mode. |
AIR FILTRATION
The built-in G4 supply filter and G4 extract filter provide air filtration. CONTROL AND AUTOMATIONSpeed control by means of the four-position speed switch CDP-3/5 that enables setting low, medium, maximum speed and turning the unit off. MOUNTINGMounting to floor, ceiling or wall with fixing brackets. The correct mounted unit must provide condensate collecting and drainage and free access to the hinged side panel for servicing and filter replacement. |
Modification name |
---|
KOMFORT L 1200 |
KOMFORT L 2200 |
KOMFORT L 350 |
KOMFORT L 500 |
KOMFORT L 530 |
KOMFORT L 600 |
Modification name | |
---|---|
KOMFORT L 1200 | |
KOMFORT L 2200 | |
KOMFORT L 350 | |
KOMFORT L 500 | |
KOMFORT L 530 | |
KOMFORT L 600 |
|
|
|
|
|
|
Series | Spigot modification | Rated air flow [m³/h] |
KOMFORT | L: horizontal spigot orientation | 350; 500; 530; 600; 1200; 2200 |
KOMFORT L 350 | KOMFORT L 500 | KOMFORT L 530 | KOMFORT L 600 | KOMFORT L 1200 | KOMFORT L 2200 | ||
G4 panel filter | ![]() |
FP 378x210x47 G4 | FP 436х215х48 G4 | FP 436х215х48 G4 | FP 436х215х48 G4 | FP 450x295x48 G4 | FP 750x295x48 G4 |
Silencer | ![]() |
SD 125 | SD 150 | SD 160 | SD 200 | SD 250 | SD 315 |
Backdraft air damper | ![]() |
VRV 125 | VRV 150 | VRV 160 | VRV 200 | VRV 250 | VRV 315 |
Air damper | ![]() |
VK 125 | VK 150 | VK 160 | VK 200 | VK 250 | VK 315 |
Summer block | ![]() |
SB C4 200/384 | SB C4 300/384 | SB C4 300/384 | SB C4 300/384 | SB C4 300/450 | SB C4 300/750 |