Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Language: EN

Blauberg KWK (rectangular)

  • Description
  • Modifications
  • Downloads
  • Designation key
  • Pressure losses
Description
Description
FEATURES

Supply air cooling for ventilation systems in various premises. Suitable for installation into supply ventilation or into air handling units to provide air cooling.

DESIGN

Galvanized steel casing. The cooling elements are made of copper tubes and aluminum plates. Available in three-coil modifications and rated for maximum operating pressure 1.5 MPa (15 bar). Polypropylene droplet separator and drain pan for condensate drainage and removal included. Droplet separator is efficient at an air flow not exceeding 4 m/s.

 
Counter air flow connection   Air flow streamwise connection
  MOUNTING

Only horizontal mounting by means of flanged connection. Air evacuation and condensate drainage must be provided. Air filter installation upstream of the cooling unit to prevent the unit soiling. Installation position must ensure uniform air flow distribution in the section. Mounting upstream or downstream of the supply fan. The minimum air duct length downstream of the fan must be 1 m to ensure air flow stabilization. The maximum cooling capacity is attained if the cooling unit is connected on counter-flow basis. The attached charts are valid for counter-flow connection. If water is used as a cooling agent, the cooling unit is suitable for indoor use only with the ambient temperature not below 0 °C. If antifreezing solution, for example, ethylene glycol solution, is used as a cooling agent, the cooling unit is suitable for outdoor use as well. While mounting the cooling unit provide condensate drainage through the U-trap. The U-trap height must be selected with respect to the total fan pressure, refer to the table and diagram below.

 
H [mm] K [mm] P [Pa]
100 55 600
200 105 1100
260 140 1400

H – U-trap heightK – drain heightP – total fan pressure

For a proper and safe operation of the cooling unit it should be connected to a control system for integral control and automatic cooling capacity regulation.

Modifications
Modification name
KWK 100x50-3
KWK 40x20-3
KWK 50x25-3
KWK 50x30-3
KWK 60x30-3
KWK 60x35-3
KWK 70x40-3
KWK 80x50-3
KWK 90x50-3
+
+
+
+
+
+
+
+
+
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
KWK (rectangular) - data sheet (pdf 714.22Kb)
KWK (rectangular) - user's manual (pdf 2.3Mb)
KWK (rectangular) - image (png 595.07Kb)
Designation key
Designation key
Series Flange size (WxH) [cm]   Number of water (glycol) coil rows
KWK 40x20; 50x25; 50x30; 60x30; 60x35; 70x40; 80x50; 90x50; 100x50 3
Pressure losses
Pressure losses