Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Transported air temperature | Voltage | Regulator | Air pass | Maximum air flow | SFP | Weight | ErP | Maximum air flow | Motor IP rating | LED-light power | * | *** |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Box-R 125 V2 (1 speed) | 1 ~ 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.18 | - | - | - | 50 | 1960 | - | 220 | Exhaust, Supply | 6.0 | 42 | 50 | C | IPX4 | - | 39 | - | - | - | - | - | - | - | - | 61 | - | - | - | - |
Box-R 125 V2 (2 speed) | 1 ~ 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.22 | - | - | - | 50 | 2610 | - | 300 | Exhaust, Supply | 6.0 | 48 | 50 | C | IPX4 | - | 45 | - | - | - | - | - | - | - | - | 83 | - | - | - | - |
BlauPlast RVPK 100 | - | - | - | - | 100 | for round air ducts | - | - | - | - | - | - | round | - | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RR 125/0.35 | - | - | - | - | 125 | - | - | - | - | - | - | - | round | 350 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 370x130T | - | - | door mounting | - | - | - | - | - | - | - | - | - | rectangular | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Aero Still Vintage 125 | 220-240 | Vintage | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | - | 9.4 | 158 | 31 | 50 | - | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 44 | 0.21 | - | - | - | - | - | - | - |
Turbo 315 min | 230 | - | Inline | mixed-flow | 315 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 0.99 | - | 1420 | - | 50/60 | 2115 | - | - | Exhaust, Supply | 11.7 | 227 | 60 | – | IPX4 | 1 | 41 | - | - | - | - | 394 | - | - | 2018 | - | IP44 | - | - | - |
Turbo 315 max | 230 | - | Inline | mixed-flow | 315 | for round air ducts | - | - | plastic | no | no | no | - | - | - | - | 1.42 | - | 1750 | - | 50/60 | 2505 | - | - | Exhaust, Supply | 11.7 | 315 | 60 | – | IPX4 | 1 | 52 | - | - | - | - | 486 | - | - | 2018 | - | IP44 | - | - | - |
Extero 160 50 Hz |
230 | - | Inline | centrifugal | 160 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 0.41 | - | 650 | - | 50 | 2440 | - | - | Exhaust | - | 95 | +55 | B | IPX4 | 1 | 60 | - | - | - | - | 181 | - | 4.5 | 2018 | - | IP44 | - | - | - |
Extero 160 60 Hz |
230 | - | Inline | centrifugal | 160 | for round air ducts | - | - | polymer-coated steel | no | yes | no | - | - | - | - | 0.42 | - | 685 | - | 60 | 2400 | - | - | Exhaust | - | 96 | +55 | B | IPX4 | 1 | 60 | - | - | - | - | 190 | - | 4.5 | 2018 | - | IP44 | - | - | - |
Decor 140x300Gs | - | - | wall mounting | rectangular flange | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | gravity | 0.0128 | - | - | - | - | - | - | - | - | - |
Ducto Plus 125 min | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.065 | 10 | 155 | 29* | 50 | 1950 | min | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | 43 | 0.23 | 0.75 | - | - | - | - | - | - |
Ducto Plus 125 max | 220-240 | White | Inline | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 13 | 215 | 33* | 50 | 2250 | max | - | Exhaust, Supply | - | - | - | - | - | - | - | - | - | - | - | 60 | 0.22 | 0.75 | - | - | - | - | - | - |
DECOR 86x230 | - | - | - | - | - | for rectangular air ducts | - | - | - | - | - | - | rectangular | - | plastic | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro Hi-Tech Gold 150 | 220-240 | Hi-Tech Gold | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 24 | 265 | 37* | 50 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 74 | 0.33 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Box 125 | 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.26 | - | - | - | 50 | 2500 | - | 340 | Exhaust, Supply | 4.55 | 58 | -25 +50 | B | IPX4 | - | 48 | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauPlast RVP 125 | - | - | - | - | 125 | for round air ducts | - | - | - | - | - | - | round | - | plastic | connector | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo 200 Light T (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | 50 | 714 | min | - | Exhaust | - | - | - | C*** | IPX4 | - | - | - | - | - | - | 36 | 0.55 | 6.4 | - | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 Light T (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | 50 | 1026 | max | - | Exhaust | - | - | - | C*** | IPX4 | - | - | - | - | - | - | 58 | 0.50 | 6.4 | - | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 Light T (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | 60 | 588 | min | - | Exhaust | - | - | - | C*** | IPX4 | - | - | - | - | - | - | 36 | 0.58 | 6.4 | - | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Ceileo 200 Light T (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | 60 | 936 | max | - | Exhaust | - | - | - | C*** | IPX4 | - | - | - | - | - | - | 63 | 0.54 | 6.4 | - | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | For fans with humidity or motion sensors |
Bravo Platinum 125 (127-220V/60Hz) | 127 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.119 | 16 | 189 | 34* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.3 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Platinum 125 (127-220V/60Hz) | 220 | Platinum | ceiling mounting, wall mounting | axial | 125 | - | - | - | - | - | - | - | - | - | - | - | 0.102 | 15 | 189 | 34* | 60 | 2400 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 53 | 0.29 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Сentro-M 355 L (50 Hz) | 230 | - | Inline | centrifugal | 355 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 1.06 | - | 2250 | - | 50 | 1375 | - | - | Exhaust, Supply | - | 233 | - | - | IPX4 | 1 | 58 | -25...+45 | - | - | - | 625 | - | 18.8 | 2018 | - | IP44 | - | - | - |
Сentro-M 355 L (60 Hz) | 230 | - | Inline | centrifugal | 355 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 1.30 | - | 2350 | - | 60 | 1620 | - | - | Exhaust, Supply | - | 297 | - | - | IPX4 | 1 | 59 | -25…+45 | - | - | - | 653 | - | 18.8 | - | - | IP44 | - | - | - |
Box-D 125 L (50 Hz) | 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.34 | - | - | - | 50 | 2300 | - | 225 | Exhaust | 2.9 | 56 | -25 +45 | C | IPX4 | 1 | 43 | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box-D 125 L (60 Hz) | 230 | - | Inline | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.35 | - | - | - | 60 | 2570 | - | 240 | Exhaust | 2.9 | 58 | -25 +45 | C | IPX4 | 1 | 44 | - | - | - | - | - | - | - | - | - | - | - | - | - |
BlauFlex AF M0/102/6 | - | - | - | - | 102 | - | - | - | - | - | - | - | - | 6000 | - | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ducto-U Power Plus 150 min | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.103 | 22 | 285 | 38* | 50/60 | 2300 | - | - | Exhaust, Supply | 1.3 | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ducto-U Power Plus 150 max | 220-240 | White | Inline | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.109 | 25 | 375 | 41* | 50/60 | 2600 | - | - | Exhaust, Supply | 1.3 | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
BlauPlast RRT 125 | - | - | - | - | - | for round air ducts | - | - | - | - | - | - | round | 198 | plastic | T-joint | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Quatro Hi-Tech Chrome 150 (127-220V/60Hz) | 127 | Hi-Tech Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.175 | 25 | 240 | 37* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Quatro Hi-Tech Chrome 150 (127-220V/60Hz) | 220 | Hi-Tech Chrome | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.338 | 25 | 240 | 37* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 67 | 0.37 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Centro-MZ 125 50 Hz |
230 | - | ceiling mounting, wall mounting | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.34 | - | 330 | - | 50 | 2820 | - | - | Supply and exhaust | 3.16 | 78 | - | C | IPX4 | - | 46 | -25...+55 | - | - | - | 92 | - | - | 2018 | - | IP44 | - | - | - |
Centro-MZ 125 60 Hz |
230 | - | ceiling mounting, wall mounting | centrifugal | 125 | for round air ducts | - | - | galvanized steel | no | no | no | - | - | - | - | 0.34 | - | 340 | - | 60 | 2880 | - | - | Supply and exhaust | 3.16 | 79 | - | C | IPX4 | - | 46 | -25...+50 | - | - | - | 94 | - | - | 2018 | - | IP44 | - | - | - |
BlauPlast RB 150/90° | - | - | - | - | 150 | for round air ducts | - | 189 | - | - | - | - | round | - | plastic | bend 90 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Ceileo 200 Light (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.1 | 20 | 130 | 24* | 50 | 714 | min | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | 36 | 0.55 | 6.4 | - | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 200 Light (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.13 | 29 | 210 | 27* | 50 | 1026 | max | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | 58 | 0.50 | 6.4 | - | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 200 Light (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.11 | 21 | 130 | 24* | 60 | 588 | min | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | 36 | 0.58 | 6.4 | - | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Ceileo 200 Light (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 34 | 225 | 28* | 60 | 936 | max | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | 63 | 0.54 | 6.4 | - | - | - | 2 х 10 | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |
Bravo Platinum 100 | 220-240 | Platinum | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 14 | 101 | 35* | 50 | 2300 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | 28 | 0.5 | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan | - |