Mode | Voltage | Style | Mounting | Design | Connection diameter | Air duct | Width | Height | Casing material | EC motor | Outdoor mounting | Sound-insulated casing | Form | Length | Material | Device | Current | Power | Maximum air flow | Sound pressure level | Frequency | RPM | Speed | Maximum air capacity | Type | Weight | Power | Max. operating temperature | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Transported air temperature | Filter | Transported air temperature | Outdoor sound pressure attenuation in accordance with DIN EN 20140 | Voltage | Maximum air flow | SFP | Weight | ErP | Air flow in heat recovery mode | Air flow in heat recovery mode | Motor IP rating | Current | Sound pressure level at 1 m in accordance with ISO 3741:2004 | Sound pressure level at 3 m in accordance with ISO 3741:2004 | Heat recovery efficiency in accordance with DIBt LÜ-A 20 | LED-light power | Functions | Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8 | * |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Box 100x50 4D | 400 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | - | - | 15000 | - | 50 | 1360 | - | - | Exhaust, Supply | 126.0 | 3800 | - | - | IPX4 | 3 | 70 | - | - | -20...+40 | - | - | 4167 | - | - | 2016, 2018 | - | - | IP44 | 6.6 | - | - | - | - | - | - | - |
Ceileo 300 Light (50 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.15 | 31 | 220 | 28* | 50 | 936 | min | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 61 | 0.51 | 6.2 | - | - | - | - | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 300 Light (50 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.22 | 49 | 300 | 31* | 50 | 1254 | max | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 83 | 0.59 | 6.2 | - | - | - | - | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 300 Light (60 Hz, min) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.17 | 35 | 200 | 27* | 60 | 888 | min | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 56 | 0.63 | 6.2 | - | - | - | - | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Ceileo 300 Light (60 Hz, max) | 230 | - | ceiling mounting | centrifugal | - | - | - | - | - | - | - | - | - | - | - | - | 0.28 | 63 | 320 | 32* | 60 | 1320 | max | - | Exhaust | - | - | - | - | IPX4 | - | - | - | - | - | - | - | 89 | 0.71 | 6.2 | - | - | - | - | - | - | - | - | 2 х 10 | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Iso-ZS 250 6E | 230 | - | - | centrifugal | - | for round air ducts | - | - | galvanized steel | no | no | yes | - | - | - | - | 0.55 | - | - | - | 50 | 860 | - | 1210 | Exhaust, Supply | 30.0 | 120 | -20…+50 | C | IPX4 | 1 | 40 | - | - | - | - | - | - | - | - | 2018 | - | - | - | - | - | - | - | - | - | - | - |
Aero Chrome 100 (127-220V/60Hz) | 127 | Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.115 | 10 | 92 | 34* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 26 | 0.39 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Aero Chrome 100 (127-220V/60Hz) | 220 | Chrome | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.054 | 9 | 92 | 34* | 60 | 2500 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 26 | 0.35 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Box-I 40x20 2E 50 Hz |
230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | 0.6 | - | 930 | - | 50 | 2600 | - | - | Exhaust, Supply | 24.5 | 138 | - | - | IPX4 | 1 | 45 | - | - | -25…+45 | - | - | 258 | - | - | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Box-I 40x20 2E 60 Hz |
230 | - | Inline | centrifugal | - | for rectangular air ducts | - | - | galvanized steel | - | - | - | - | - | - | - | 0.88 | - | 1070 | - | 60 | 2850 | - | - | Exhaust, Supply | 24.5 | 200 | - | - | IPX4 | 1 | 47 | - | - | -25…+45 | - | - | 297 | - | - | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Axis-QR 300 4D 50 Hz |
400 | - | wall mounting | axial | 300 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | 1310 | - | 50 | 1380 | - | - | Exhaust, Supply | - | 75 | - | - | IPX4 | 3 | 45 | - | - | -30...+60 | - | - | 364 | - | 5.1 | - | - | - | IP44 | 0.22 | - | - | - | - | - | - | - |
Axis-QR 300 4D 60 Hz |
400 | - | wall mounting | axial | 300 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | 1530 | - | 60 | 1640 | - | - | Exhaust, Supply | - | 94 | - | - | IPX4 | 3 | 45 | - | - | -30...+50 | - | - | 425 | - | 5.1 | - | - | - | IP44 | 0.25 | - | - | - | - | - | - | - |
Quatro Platinum 100 | 220-240 | Platinum | ceiling mounting, wall mounting | axial | 100 | - | - | - | - | - | - | - | - | - | - | - | 0.085 | 14 | 88 | 33* | 50 | 2300 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 24 | 0.57 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
BlauPlast RTR 125/0.5-1 | - | - | - | - | 125 | - | - | - | - | - | - | - | round | 500-1000 | PVC (plastic) | air duct | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Box 160 | 230 | - | Inline | centrifugal | 160 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | 0.38 | - | - | - | 50 | 2600 | - | 553 | Exhaust, Supply | 6.6 | 85 | -25 +40 | B | IPX4 | - | 50 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Decor 370x130T-2 | - | - | door mounting | - | - | - | - | - | - | - | - | - | rectangular | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Iso 160-2Е | 230 | - | Inline | centrifugal | - | for round air ducts | - | - | aluzinc | no | no | yes | - | - | - | - | 1.16 | - | 730 | - | 50 | 2600 | - | - | Exhaust, Supply | 6.28 | 335 | -25 +40 | - | IPX4 | - | 37.9 | - | - | - | - | - | 203 | - | - | 2018 | - | - | IP44 | - | - | - | - | - | - | - | - |
Vento Expert Duo A30-1 S10 Pro (1 speed) |
100-240 | - | - | - | - | 160 | - | - | - | yes | - | - | - | - | - | - | 0.027 | - | 10 | - | 50/60 | 1600 | - | - | - | - | 2.00 | - | - | IP24 | - | - | -15…+40 | G3 | - | 42 | - | 3 | 0.72 | - | - | 60 | 16 | - | - | 33 | 24 | up to 85 | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | D2 | - |
Vento Expert Duo A30-1 S10 Pro (2 speed) |
100-240 | - | - | - | - | 160 | - | - | - | yes | - | - | - | - | - | - | 0.043 | - | 20 | - | 50/60 | 2200 | - | - | - | - | 3.70 | - | - | IP24 | - | - | -15…+40 | G3 | - | 42 | - | 6 | 0.67 | - | - | 60 | 16 | - | - | 40 | 31 | up to 85 | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | D2 | - |
Vento Expert Duo A30-1 S10 Pro (3 speed) |
100-240 | - | - | - | - | 160 | - | - | - | yes | - | - | - | - | - | - | 0.067 | - | 30 | - | 50/60 | 2500 | - | - | - | - | 6.40 | - | - | IP24 | - | - | -15…+40 | G3 | - | 42 | - | 8 | 0.77 | - | - | 60 | 16 | - | - | 43 | 34 | up to 85 | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | D2 | - |
Axis-F 800 6D | 400 | - | Inline | axial | 800 | for round air ducts | - | - | polymer-coated steel | no | no | no | - | - | - | - | - | - | 25000 | - | 50 | 915 | - | - | Exhaust, Supply | - | 1850 | - | - | IPX4 | 3 | 67 | - | - | -30...+60 | - | - | 6945 | - | 40.0 | - | - | - | IP44 | 3.7 | - | - | - | - | - | - | - |
Bravo Platinum 150 (127-220V/60Hz) | 127 | Platinum | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.175 | 25 | 266 | 38* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 74 | 0.34 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |
Bravo Platinum 150 (127-220V/60Hz) | 220 | Platinum | ceiling mounting, wall mounting | axial | 150 | - | - | - | - | - | - | - | - | - | - | - | 0.338 | 25 | 266 | 38* | 60 | 2350 | - | - | Exhaust | - | - | - | - | - | - | - | - | - | - | - | - | 74 | 0.34 | - | - | - | - | - | - | - | - | - | - | - | - | Sound pressure level measured in free space at a distance of 3 meters from the fan |