Selected 969 products
Mode VoltageStyleMountingDesignConnection diameterAir ductWidthHeightCasing materialEC motorOutdoor mountingSound-insulated casingHeatingFormLengthMaterialDeviceCurrentPowerMaximum air flowSound pressure levelFrequencyRPMSpeedMaximum air capacityTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialTransported air temperature Connected air duct diameterTransported air temperatureInsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionMaximum air flowSFPWeightErPMaximum air flowExtract filterSupply filterMotor IP ratingMax. power without electric heaterMax. unit current without electric heaterMax. unit power with electric heaterMax. unit current with electric heaterCurrentPreheater power consumptionRemote control panelFunctionsCable cross section*Motor max. power***
Box EC 90x50-3 max 400 - Inline centrifugal - for rectangular air ducts - - galvanized steel yes no - - - - - - - - 11190 - 50/60 1800 - - Exhaust, Supply 72.0 3429 - IPX4 3 66 - - - - -25...+50 - - - - - - 3109 - - 2018 - - - IP54 - - - - 5.00 - - - - - - -
KOMFORT EC LB 700 S14 230 - ceiling mounting, floor mounting - - - - - galvanized steel - - - - - - - - - - 830 - 50/60 3200 - - - - - - A+ - 1 31 counter-flow polystyrene - 250 -25…+40 40 mm mineral wool 80–98 - - - - 231 - 107 - - G4 G4, F7 - 336 2.4 - - - - - - - - - -
Iso-ZS 315/2x250 4E max 230 - - centrifugal - for round air ducts - - galvanized steel no no yes - - - - - 4.78 - - - 50 1455 - 3930 Exhaust, Supply 38.0 1066 -20…+50 - IPX4 1 47 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Aero Still Chrome 100 220-240 Chrome ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.035 5.5 84 25* 50 - - - Exhaust - - - - - - - - - - - - - - - - - - 23 0.24 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
BlauPlast RR 100/0.35 - - - - 100 - - - - - - - - round 350 PVC (plastic) air duct - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Axis-QR 500 4D
50 Hz
400 - wall mounting axial 500 for round air ducts - - polymer-coated steel no no no - - - - - - - 6570 - 50 1300 - - Exhaust, Supply - 450 - - IPX4 3 60 - - - - -30...+60 - - - - - - 1825 - 14.0 - - - - IP24 - - - - 0.9 - - - - - - -
Axis-QR 500 4D
60 Hz
400 - wall mounting axial 500 for round air ducts - - polymer-coated steel no no no - - - - - - - 6230 - 60 1605 - - Exhaust, Supply - 370 - - IPX4 3 60 - - - - -30...+50 - - - - - - 1731 - 14.0 - - - - IP24 - - - - 0.7 - - - - - - -
Auto 100 220-240 White wall mounting axial 100 - - - - - - - - - - - - 0.085 18 98 34* 50 2300 - - Exhaust - - - - - - - - - - - - - - - - - - 27 0.66 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Iso-RB 100 230 - Inline centrifugal 100 for round air ducts - - aluzinc no no yes - - - - - 0.25 - 285 - 50 2530 - - Exhaust, Supply - 58 - C IPX4 1 34 - - - - -25…+55 - - - - - - 79 - 13 2018 - - - IP44 - - - - - - - - - - - -
Tower-A 350 4Е (60 Hz) 230 - for roof axial - for round air ducts - - polymer-coated steel no yes no - - - - - 0.66 - 2650 - 60 1700 - - Exhaust 12.0 147 -30…+50 - IP24 1 63 - - - - - - - - - - - 736 - - 2018 - - - IP44 - - - - - - - - - - - -
Tower-A 350 4Е (50 Hz) 230 - for roof axial - for round air ducts - - polymer-coated steel no yes no - - - - - 0.65 - 2500 - 50 1380 - - Exhaust 12.0 140 -30…+60 - IP24 1 62 - - - - - - - - - - - 695 - - 2018 - - - IP44 - - - - - - - - - - - -
Box-D 100 L (50 Hz) 230 - Inline centrifugal 100 for round air ducts - - galvanized steel no no no - - - - - 0.34 - - - 50 2300 - 190 Exhaust 2.9 56 -25 +45 C IPX4 1 42 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-D 100 L (60 Hz) 230 - Inline centrifugal 100 for round air ducts - - galvanized steel no no no - - - - - 0.35 - - - 60 2570 - 205 Exhaust 2.9 58 -25 +45 C IPX4 1 43 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ceileo Compact 250 T
(50 Hz, min)
220-240 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.12 23 170 25* 50 756 min - Exhaust - - - C*** IPX4 - - - - - - - - - - - - - 47 0.49 5.3 - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - For fans with humidity or motion sensors
Ceileo Compact 250 T
(50 Hz, max)
220-240 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.18 39 260 29* 50 1122 max - Exhaust - - - C*** IPX4 - - - - - - - - - - - - - 72 0.54 5.3 - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - For fans with humidity or motion sensors
Ceileo Compact 250 T
(60 Hz, min)
220-240 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.14 25 160 25* 60 732 min - Exhaust - - - C*** IPX4 - - - - - - - - - - - - - 44 0.56 5.3 - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - For fans with humidity or motion sensors
Ceileo Compact 250 T
(60 Hz, max)
220-240 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.22 50 270 30* 60 1140 max - Exhaust - - - C*** IPX4 - - - - - - - - - - - - - 75 0.67 5.3 - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - For fans with humidity or motion sensors
Valeo-E 75/100
(1 speed)
- - ceiling mounting, wall mounting centrifugal - for round air ducts - - plastic no no - - - - - - 0.11 - 75 29* 50 - I - Exhaust - 24 +50 - - - - - - - - - - - - 220-240 - - 21 - - - - - - IP55 - - - - - - - - 3x1.5 Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Valeo-E 75/100
(2 speed)
- - ceiling mounting, wall mounting centrifugal - for round air ducts - - plastic no no - - - - - - 0.13 - 100 38* 50 - II - Exhaust - 29 +50 - - - - - - - - - - - - 220-240 - - 28 - - - - - - IP55 - - - - - - - - 3x1.5 Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Box-F 70x40 4D 400 - Inline centrifugal - for rectangular air ducts 700 400 galvanized steel no no no - - - - - 6.00 - 6450 - 50 1320 - - Exhaust, Supply - 3630 -25...+40 - IPX4 3 65 - - - - - - - - - - - 1792 - 60.0 - - - - IP44 - - - - - - - - - - - -
KOMFORT Roto EC LW 1200-2 S17 230 - - - - - - - aluzinc - - - - - - - - - - 1200 - 50/60 1930 - - - - - - - - 1 60 rotary aluminum - 315 -25...+40 20 mm mineral wool 73–95 - - - - 333 - 165 2016, 2018 - G4 G4 - - - 570 2.5 - - - - - - 2 items x 208 -
Iso-K 400 6E 230 - Inline centrifugal 400 for round air ducts - - galvanized steel no yes yes - - - - - 1.71 - - - 50 930 - 2915 Exhaust - 362 -20…+120 - IP54 1 48 - - - - - - - - - - - - - 87 - 810 - - IP54 - - - - - - - - - - - -
Bravo 125 (127-220V/60Hz) 127 White ceiling mounting, wall mounting axial 125 - - - - - - - - - - - - 0.119 16 189 34* 60 2400 - - Exhaust - - - - - - - - - - - - - - - - - - 53 0.3 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Bravo 125 (127-220V/60Hz) 220 White ceiling mounting, wall mounting axial 125 - - - - - - - - - - - - 0.102 15 189 34* 60 2400 - - Exhaust - - - - - - - - - - - - - - - - - - 53 0.29 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
CIVIC EC LBE 300 S21 230 - floor mounting - - - - - polymer-coated steel yes - - electric preheating - - - - - - 320 - 50/60 2150 - - Supply and exhaust 139±3% - - A - 1 21 counter-flow polystyrene -25...+40 200 - 40 mm mineral wool 78...92* 31 - 125 - 89 - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - 0.9 - 7 - 1400 Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - Heat recovery efficiency is specified in compliance with EN 13141-8 - -
Tower-H 355 4D 400 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - - - - - 0.58 - 3290 - 50 1430 - - Exhaust 30.3 264 -30…+60 - IPX4 3 52 - - - - - - - - - - - 914 - - 2018 - - - IP54 - - - - - - - - - - - -
Tower-H 355 4D (60 Hz) 400 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - - - - - 0.64 - 3540 - 60 1650 - - Exhaust 30.3 330 -30…+60 - IPX4 3 53 - - - - - - - - - - - 983 - - - - - IP54 - - - - - - - - - - - -
Centro 315 230 - Inline centrifugal 315 for round air ducts - - plastic no no no - - - - - 0.88 - 1340 - 50 2655 - - Exhaust, Supply - 200 -25...+55 - IPX4 1 48 - - - - - - - - - - - 372 - 4.85 2018 - - - IP44 - - - - - - - - - - - -
Ceileo 250 (50 Hz, min) 230 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.12 23 170 25* 50 756 min - Exhaust - - - - IPX4 - - - - - - - - - - - - - 47 0.49 5.3 - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Ceileo 250 (50 Hz, max) 230 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.18 39 260 29* 50 1122 max - Exhaust - - - - IPX4 - - - - - - - - - - - - - 72 0.54 5.3 - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Ceileo 250 (60 Hz, min) 230 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.14 25 160 25* 60 732 min - Exhaust - - - - IPX4 - - - - - - - - - - - - - 44 0.56 5.3 - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Ceileo 250 (60 Hz, max) 230 - ceiling mounting centrifugal - - - - - - - - - - - - - 0.22 50 270 30* 60 1140 max - Exhaust - - - - IPX4 - - - - - - - - - - - - - 75 0.67 5.3 - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
S-Vent 240x114-2.2-4D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - - - - - 5.1 - - - 50 1420 - 2930 Exhaust, Supply 30.5 2200 60 - IP54 - 74 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box EC 60x35-3 max 400 - Inline centrifugal - for rectangular air ducts - - galvanized steel yes no - - - - - - - - 4290 - 50/60 3160 - - Exhaust, Supply 36.0 1308 - IPX4 3 55 - - - - -25...+50 - - - - - - 1192 - - 2018 - - - IP54 - - - - 2.35 - - - - - - -
KOMFORT EC LB 400 S14 230 - ceiling mounting, floor mounting - - - - - galvanized steel - - - - - - - - - - 540 - 50/60 2600 - - - - - - A+ - 1 27 counter-flow polystyrene - 200 -25…+40 40 mm mineral wool 84–98 - - - - 150 - 74.8 - - G4 G4, F7 - 289 2.1 - - - - - - - - - -
Iso-ZS 315 4E 230 - - centrifugal - for round air ducts - - galvanized steel no no yes - - - - - 3.15 - - - 50 1350 - 3200 Exhaust, Supply 33.0 723 -20…+50 - IPX4 1 45 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Sileo V2 100 min - White ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.029 4.5 60 22* 50 1850 - - Exhaust - - - - - - - - - - - - - - - 220-240 - - 17 0.27 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -
Sileo V2 100 max - White ceiling mounting, wall mounting axial 100 - - - - - - - - - - - - 0.052 7 90 25* 50 2400 - - Exhaust - - - - - - - - - - - - - - - 220-240 - - 25 0.28 - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan - -