Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. Reduction of heat losses in cold climate conditions and load for air conditioning systems in hot climate conditions due to heat and humidity recovery. Control of air exchange for creating comfortable indoor microclimate. Compatible with round Ø 150 mm air ducts. DESIGNThe casing is made of 15–30 mm thick expanded polypropylene (EPP) with high heat and sound-insulating properties.The spigots are located at the side of the unit and are rubber sealed for airtight connection to the air ducts. |
FANS
Single-phase three-speed external rotor motors with centrifugal impellers and forward curved blades. Integrated motor overheating protection with automatic restart. |
|
HEAT RECOVERY
The KOMFORT D5 180 unit is equipped with a plate counter-flow polystyrene heat exchanger for heat recovery. The unit condensate is collected and drained to the drain pan under the heat exchanger. The KOMFORT D5 180-E unit is equipped with an enthalpy plate counter-flow heat exchanger for energy (heat and humidity) recovery. Due to humidity recovery condensate is not generated in the enthalpy heat exchanger.The air flows are completely separated in the heat exchanger. Thus smells and contaminants are not transferred from the extract air to the supply air. Heat recovery is based on heat and/or humidity transfer through the heat exchanger plates. In the cold season supply air is heated in the heat exchanger by transferring the heat energy of warm and humid extract air to the cold fresh air. Heat recovery minimizes ventilation heat losses and heating costs respectively. In the warm season the heat exchanger performs reverse and intake air is cooled in the heat exchanger by the cool extract air. That reduces operation load on air conditioners and saves electricity. FREEZE PROTECTIONThe freeze protection of the heat exchanger is activated by shutdown on the supply fan as follows: in case of freezing danger communicated by the temperature sensor the supply fan turns off for the time required for defrosting of the heat exchanger with the warm extract air flow. After freezing danger is no longer imminent, the unit reverts to the standard operation mode. |
AIR FILTRATION
Two built-in G4 and F7 filters provide efficient supply air filtration. The G4 filter is used for extract air filtration. CONTROL AND AUTOMATIONThe units have integrated control system based on the mechanical three-speed speed switch CDP-3/5 (KOMFORT D5 180 S3) or sensor three-speed speed switch SGR-3/1 (KOMFORT D5 180 S4) and power cable with mains plug.The control unit is integrated in the unit casing. The power and ground cables are connected to the control unit via the cable glands on the side of the unit. MOUNTINGThe units are designed for suspended ceiling, wall and horizontal floor mounting. The correct mounted unit must provide service access for maintenance and filter replacement. |
Modification name |
---|
KOMFORT D5 180 S3 |
KOMFORT D5 180 S4 |
KOMFORT D5 180-E S3 |
KOMFORT D5 180-E S4 |
Modification name | |
---|---|
KOMFORT D5 180 S3 | |
KOMFORT D5 180 S4 | |
KOMFORT D5 180-E S3 | |
KOMFORT D5 180-E S4 |
|
|
|
|
- Selection method:
- Air capacity:
- Pressure:
- Air capacity: --
- Pressure: ---
KOMFORT D5 180 S3 KOMFORT D5 180 S4 |
KOMFORT D5 180-E S3 KOMFORT D5 180-E S4 |
||
G4 panel filter | FP 214x186x18 G4 | FP 214x186x18 G4 | |
F7 panel filter | FP 214x186x48 F7 | FP 214x186x48 F7 | |
Syphon kit | SFK 20x32 | – |