FEATURES
Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. Heat and humidity recovery reduces ventilation heat losses in the cold season and the load on the air conditioners in the hot season. Heat recovery minimises ventilation heat losses. Control of air exchange for creating comfortable indoor microclimate. Compatible with round Ø 125 mm air ducts. DESIGNThe casing of KOMFORT Ultra L 250-H(E) S12 is made of double-skinned aluzinc panels, internally filled with 20 mm mineral wool layer for heat and sound insulation. The casing of KOMFORT Ultra L 250-H(E) S12 white is made of double-skinned white painted metal panels, internally filled with 20 mm mineral wool layer for heat and sound insulation. The spigots are located at the side of the unit and are rubber sealed for airtight connection to the air ducts. The hinged panel of the casing ensures easy access to the unit internals for service works including cleaning, filter replacement, etc. |
Asynchronous external rotor motors and centrifugal impellers with backward curved blades are used for air supply and exhaust. Integrated motor overheating protection with automatic restart. Dynamically balanced impellers. Equipped with ball bearings for longer service life.Reliable and quiet operation. |
|
|
||
HEAT RECOVERY
The integrated automatic freeze protection is used to prevent freezing of the heat exchanger in the cold season. The supply fan turns off according to the temperature sensor to get the heat exchanger warmed up with extract air. After that the supply fan turns on and the unit continues to run in the standard mode. |
AIR FILTRATION
The built-in G4 supply filter and G4 extract filter provide air filtration. The F8 supply filter (specially ordered accessory) may be used for efficient supply air filtration. CONTROL AND AUTOMATIONSmooth motor speed control from 0 up to 100 % by means of the thyristor speed controller SGS E1 (included in the delivery). MOUNTINGThe units can be fixed to the wall or mounted on the floor using the mounting brackets. The KOMFORT Ultra L 250-E S12 (white) unit is also suitable for ceiling mounting. The KOMFORT Ultra L 250-H S12 (white) unit mounting position must provide condensate collection and drainage. While mounting provide free access to the service panel for filter replacement and servicing. Due to universal casing design both left and right mounting is possible. It requires swapping the service and the back panel. |
Modification name |
---|
KOMFORT Ultra L 250-E S12 |
KOMFORT Ultra L 250-E S12 white |
KOMFORT Ultra L 250-H S12 |
KOMFORT Ultra L 250-H S12 white |
Modification name | |
---|---|
KOMFORT Ultra L 250-E S12 | |
KOMFORT Ultra L 250-E S12 white | |
KOMFORT Ultra L 250-H S12 | |
KOMFORT Ultra L 250-H S12 white |
|
|
|
|
- Selection method:
- Air capacity:
- Pressure:
- Air capacity: --
- Pressure: ---
Series | Unit type | Spigot modification | Rated air flow [m³/h] | Heat exchanger type | Control | Casing | |
KOMFORT | Ultra: compact unit | L: horizontal spigot orientation | 250 | – | Н: heat recovery Е: energy recovery |
S12: speed controller SGS E1 | _: aluzinc white: white-painted steel |
KOMFORT Ultra L 250-H S12 KOMFORT Ultra L 250-H S12 white |
KOMFORT Ultra L 250-E S12 KOMFORT Ultra L 250-E S12 white |
||
G4 panel filter | ![]() |
FP 240x184x40 G4 | FP 240x184x40 G4 |
F8 panel filter | ![]() |
FP 240x184x40 F8 | FP 240x184x40 F8 |
Silencer | ![]() |
SD 125 | SD 125 |
Backdraft air damper | ![]() |
VRV 125 | VRV 125 |
Air damper | ![]() |
VK 125 | VK 125 |
Summer block | ![]() |
SB C4 200/240 | SB C4 200/240 |