Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Language: EN

Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Single-room reversible units Vento
  • Single-room units Freshbox
  • Single-room ventilation units Civic
Additionally
Show ×
Voltage
Functions
Remote control panel
Heating
Mounting
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 111 products
Mode VoltageMountingAir ductCasing materialEC motorHeatingCurrentPowerMaximum air flowSound pressure levelFrequencyRPMSpeedExtract / supply filterHeat recovery efficiencyTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyTransported air temperature Connected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeFilterTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140Regeneration efficiency in accordance with DIBt LÜ-A 20InsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPWeightExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeAir flow in heat recovery modeAir flow in heat recovery modeMax. power without electric heaterMax. unit current without electric heaterMax. unit current with electric heaterPreheater power consumptionReheater power consumptionMax. current consumption with heater(s)Sound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Air flow in heat recovery modeAir flow in heat recovery modeRemote control panelFunctionsIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8Power********Transported air temperature
VENTO A50 (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 - 50 599 - - - - - 3.68 - A IP24 - - - - 24 14 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - -
VENTO A50 (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 - 50 1155 - - - - - 4.83 - A IP24 - - - - 34 24 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - -
CIVIC EC LB 500 S14 230 floor mounting - polymer-coated steel yes without heating - - 580 - 50/60 1280 - - - Supply and exhaust 191±3% - - A - 1 25 counter-flow polystyrene - - - - -25...+40 250 - - - - - - 40 mm mineral wool 75...94* 35 - 230 - - 161 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 1.7 1.7 - - - - - - - - - Sensor Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - -
CIVIC EC LB 500 S21 230 floor mounting - polymer-coated steel yes without heating - - 580 - 50/60 1280 - - - Supply and exhaust 191±3% - - A - 1 25 counter-flow polystyrene - - - - -25...+40 250 - - - - - - 40 mm mineral wool 75...94* 35 - 230 - - 161 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 1.7 1.7 - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - -
Freshbox 100
Speed I
110-240 wall mounting - polymer-coated steel yes without heating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -15...+40 - - - 98 - - - - 10 8 - - G4 - - - - - 12 0.4 - - - - - 13 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100
Speed II
110-240 wall mounting - polymer-coated steel yes without heating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -15...+40 - - - 92 - - - - 10 17 - - G4 - - - - - 21 0.4 - - - - - 27 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox 100
Speed III
110-240 wall mounting - polymer-coated steel yes without heating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -15...+40 - - - 89 - - - - 10 28 - - G4 - - - - - 45 0.4 - - - - - 39 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
FRESHBOX 60 (1 speed) 100-240 wall mounting - - - without heating 0.02 4.2 30 22 50/60 1165 - G4 79 - 10.3 - -20...+40 B - 1 - counter-flow polystyrene - - - - - - - - - - - - - - - - - - - 8 - - - - - - - - - - - - - - - - - - - - Sensor - - - - - - - - -
FRESHBOX 60 (2 speed) 100-240 wall mounting - - - without heating 0.04 9.6 45 25 50/60 1720 - G4 74 - 10.3 - -20...+40 B - 1 - counter-flow polystyrene - - - - - - - - - - - - - - - - - - - 13 - - - - - - - - - - - - - - - - - - - - Sensor - - - - - - - - -
FRESHBOX 60 (3 speed) 100-240 wall mounting - - - without heating 0.07 15.4 60 29 50/60 2685 - G4 70 - 10.3 - -20...+40 B - 1 - counter-flow polystyrene - - - - - - - - - - - - - - - - - - - 17 - - - - - - - - - - - - - - - - - - - - Sensor - - - - - - - - -
CIVIC EC LBE 300 S14 230 floor mounting - polymer-coated steel yes electric preheating - - 320 - 50/60 2150 - - - Supply and exhaust 139±3% - - A - 1 21 counter-flow polystyrene - - - - -25...+40 200 - - - - - - 40 mm mineral wool 78...92* 31 - 125 - - 89 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 0.9 7 1400 - - - - - - - - Sensor Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - -
CIVIC EC LBE 300 S21 230 floor mounting - polymer-coated steel yes electric preheating - - 320 - 50/60 2150 - - - Supply and exhaust 139±3% - - A - 1 21 counter-flow polystyrene - - - - -25...+40 200 - - - - - - 40 mm mineral wool 78...92* 31 - 125 - - 89 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 0.9 7 1400 - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - -
VENTO Expert DUO A30-1 Pro (1 Speed) 100-240 wall mounting 160 - - - 0.027 - 10 - 50/60 1600 - - - - - 2.00 - A IP24 - - - - 33 24 - - - - - - G3 - 42 ≤ 85 - - - - - - - 3 - - - - - - 60 16 - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - -15...+40
VENTO Expert DUO A30-1 Pro (2 Speed) 100-240 wall mounting 160 - - - 0.043 - 20 - 50/60 2200 - - - - - 3.70 - A IP24 - - - - 40 31 - - - - - - G3 - 42 ≤ 85 - - - - - - - 6 - - - - - - 60 16 - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - -15...+40
VENTO Expert Duo A30-1 Pro (3 Speed) 100-240 wall mounting 160 - - - 0.067 - 30 - 50/60 2500 - - - - - 6.40 - A IP24 - - - - 43 34 - - - - - - G3 - 42 ≤ 85 - - - - - - - 8 - - - - - - 60 16 - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - -15...+40
CIVIC EC LB 300 S21 230 floor mounting - polymer-coated steel yes without heating - - 320 - 50/60 2150 - - - Supply and exhaust 138±3% - - A - 1 21 counter-flow polystyrene - - - - -25...+40 200 - - - - - - 40 mm mineral wool 78...92* 31 - 125 - - 89 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 0.9 0.9 - - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - -
VENTO Expert Duo A30-1 W (1 speed) 100-240 wall mounting 160 - - - 0.026 - 10 - 50/60 1600 - - - - - 2.17 - A IP24 - - - - 33 24 - - - - - - G3 - 42 ≤ 85 - - - - - - - 3 - - - - - - 60 16 - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - -15...+40
VENTO Expert Duo A30-1 W (2 speed) 100-230 wall mounting 160 - - - 0.039 - 20 - 50/60 2200 - - - - - 3.66 - A IP24 - - - - 40 31 - - - - - - G3 - 42 ≤ 85 - - - - - - - 6 - - - - - - 60 16 - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - -15...+40
VENTO Expert Duo A30-1 W (3 speed) 100-230 wall mounting 160 - - - 0.066 - 30 - 50/60 2500 - - - - - 6.62 - A IP24 - - - - 43 34 - - - - - - G3 - 42 ≤ 85 - - - - - - - 8 - - - - - - 60 16 - - - - - - - - - - - - - Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection - - - - - - - -15...+40
Vento Expert A50-1 S10 Pro
(1 speed)
100-240 - 160 - yes - 0.025 - - - 50/60 800 - - - - - 3.61 - - IP24 - - - - - - - - -20…+40 - 15 8 - - 42 - - - - - - - - - 1.73 - - - 4 2 - - - - - - - - 20 11 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - - Maximum air flow 40 m³/h - - - -
Vento Expert A50-1 S10 Pro
(2 speed)
100-240 - 160 - yes - 0.030 - - - 50/60 1300 - - - - - 4.15 - - IP24 - - - - - - - - -20…+40 - 30 15 - - 42 - - - - - - - - - 1.00 - - - 8 4 - - - - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - - Maximum air flow 40 m³/h - - - -
Vento Expert A50-1 S10 Pro
(3 speed)
100-240 - 160 - yes - 0.039 - - - 50/60 1900 - - - - - 5.20 - - IP24 - - - - - - - - -20…+40 - 50 25 - - 42 - - - - - - - - - 0.75 - - - 14 7 - - - - - - - - 30 21 G3 (Option: F8 PM2,5 > 99 %*) up to 93 - - - Filter replacement indication, Timer, Humidity sensor, External sensor connection D1 - - Maximum air flow 40 m³/h - - - -
VENTO Ergo A25-1 S Pro (1 speed) 100-230 wall mounting 100 - - - 0.024 - 7 - 50/60 1250 - - - - - 3.68 - A IP24 - - - - 31 22 19 ≤ 85 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
VENTO Ergo A25-1 S Pro (2 speed) 100-230 wall mounting 100 - - - 0.027 - 16 - 50/60 1397 - - - - - 4.15 - A IP24 - - - - 35 25 19 ≤ 85 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
VENTO Ergo A25-1 S Pro (3 speed) 100-230 wall mounting 100 - - - 0.038 - 25 - 50/60 2541 - - - - - 5.59 - A IP24 - - - - 43 33 19 ≤ 85 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
Vento Ergo A85 S Pro1
(1 speed)
- - 150 - - - 0.034 - 36 - 50/60 1000 I - - - - 4.74 - - IP24 1 - - - - - - - - - - 18 - -20...+40 40 - - - - 100-230 - - - 10 0.95 - - - - 5 - - - - - - - - 29 19 G3 (Option: F8 PM2,5 > 99 %*) - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
Vento Ergo A85 S Pro1
(2 speed)
- - 150 - - - 0.050 - 59 - 50/60 1500 II - - - - 6.56 - - IP24 1 - - - - - - - - - - 30 - -20...+40 40 - - - - 100-230 - - - 16 0.80 - - - - 8 - - - - - - - - 35 25 G3 (Option: F8 PM2,5 > 99 %*) - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
Vento Ergo A85 S Pro1
(3 speed)
- - 150 - - - 0.071 - 85 - 50/60 2045 III - - - - 9.65 - - IP24 1 - - - - - - - - - - 43 - -20...+40 40 - - - - 100-230 - - - 24 0.82 - - - - 12 - - - - - - - - 44 34 G3 (Option: F8 PM2,5 > 99 %*) - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
Freshbox 200 ERV WiFi
Speed I
230 - - polymer-coated steel - without heating - - 30 - 50/60 2000 I - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 85 - - - 30 8 - 55 G4 G4 + F7 (Option: H13) - - - - 10 - - - 1.0 - 12 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - -
Freshbox 200 ERV WiFi
Speed II
230 - - polymer-coated steel - without heating - - 60 - 50/60 2000 II - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 81 - - - 30 17 - 55 G4 G4 + F7 (Option: H13) - - - - 15 - - - 1.0 - 22 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - -
Freshbox 200 ERV WiFi
Speed III
230 - - polymer-coated steel - without heating - - 90 - 50/60 2000 III - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 75 - - - 30 25 - 55 G4 G4 + F7 (Option: H13) - - - - 25 - - - 1.0 - 30 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - -
Freshbox 200 ERV WiFi
Speed IV
230 - - polymer-coated steel - without heating - - 120 - 50/60 2000 IV - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 68 - - - 30 33 - 55 G4 G4 + F7 (Option: H13) - - - - 44 - - - 1.0 - 36 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - -
Freshbox 200 ERV WiFi
Speed V
230 - - polymer-coated steel - without heating - - 200 - 50/60 2000 V - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 66 - - - 30 56 - 55 G4 G4 + F7 (Option: H13) - - - - 134 - - - 1.0 - 45 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - - - - - -
Vento Eco2 A50-4 S11 Pro (1 speed) - - 160 - - - 0.033 - - - 50/60 915 I - - - - 2.37 - - IP24 - - - - - - - - - - 15 - - -20(-30**) … +40 41 - - - - 100-240 - - - - 0.57 - - - 4 - - - - - - - - - 21 12 G3 (Option: F8 PM2,5 > 99 %*) up to 92 15 4 Sensor Filter replacement indication, Timer D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - -
Vento Eco2 A50-4 S11 Pro (2 speed) - - 160 - - - 0.047 - - - 50/60 1555 II - - - - 3.80 - - IP24 - - - - - - - - - - 30 - - -20(-30**) … +40 41 - - - - 100-240 - - - - 0.46 - - - 8 - - - - - - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 92 30 8 Sensor Filter replacement indication, Timer D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - -
Vento Eco2 A50-4 S11 Pro (3 speed) - - 160 - - - 0.080 - - - 50/60 2330 III - - - - 7.61 - - IP24 - - - - - - - - - - 50 - - -20(-30**) … +40 41 - - - - 100-240 - - - - 0.55 - - - 14 - - - - - - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 92 50 14 Sensor Filter replacement indication, Timer D1 S3*** - Maximum air flow 40 m³/h With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied At III speed - -
Freshbox E-100 ERV WiFi
Speed I
230 - - polymer-coated steel - electric preheating - - 30 - 50/60 2200 I - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 96 - - - - 10 8 - 31 G4 - - - - - 20 0.4 3.6 700 - - - 13 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV WiFi
Speed II
230 - - polymer-coated steel - electric preheating - - 44 - 50/60 2200 II - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 94 - - - - 10 12 - 31 G4 - - - - - 23 0.4 3.6 700 - - - 20 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV WiFi
Speed III
230 - - polymer-coated steel - electric preheating - - 60 - 50/60 2200 III - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 89 - - - - 10 17 - 31 G4 - - - - - 29 0.4 3.6 700 - - - 27 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV WiFi
Speed IV
230 - - polymer-coated steel - electric preheating - - 75 - 50/60 2200 IV - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 85 - - - - 10 21 - 31 G4 - - - - - 37 0.4 3.6 700 - - - 33 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV WiFi
Speed V
230 - - polymer-coated steel - electric preheating - - 100 - 50/60 2200 V - - - - - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 83 - - - - 10 28 - 31 G4 - - - - - 53 0.4 3.6 700 - - - 39 - - - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO Ergo A50 Pro
(1 speed)
- wall mounting 150 - - - 0.024 - 21 - 50/60 610 - - - - - 4.5 - A IP24 - - - - 22 13 40 ≤ 88 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
VENTO Ergo A50 Pro
(2 speed)
- wall mounting 150 - - - 0.026 - 32 - 50/60 800 - - - - - 5 - A IP24 - - - - 29 20 40 ≤ 88 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
VENTO Ergo A50 Pro
(3 speed)
- wall mounting 150 - - - 0.039 - 50 - 50/60 1450 - - - - - 7 - A IP24 - - - - 32 23 40 ≤ 88 - - - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - - - - -
CIVIC EC DBE 500 S21 230 ceiling mounting - polymer-coated steel yes electric preheating - - 510 - 50/60 1700 - - - Supply and exhaust 128 - - A - 1 24 counter-flow polystyrene - - - - -25...+40 250 - - - - - - 25 mm, cellular synthetic rubber 74...86* 34 - 170 - - 142 - - G4 G4, F8 (option F8 C + H11) - - - - - 1.7 10.4 1750 - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - -
Freshbox E-100 ERV black
Speed I
230 wall mounting - polymer-coated steel yes electric preheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 90 - - - - 10 8 - - G4 - - - - - 12 0.4 3.6 700 - - - 13 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV black
Speed II
230 wall mounting - polymer-coated steel yes electric preheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 86 - - - - 10 17 - - G4 - - - - - 21 0.4 3.6 700 - - - 27 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100 ERV black
Speed III
230 wall mounting - polymer-coated steel yes electric preheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow enthalpy - - - - - 100 - - - -15...+40 - - - 83 - - - - 10 28 - - G4 - - - - - 45 0.4 3.6 700 - - - 39 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO A50-1 S Pro (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 - 50 599 - - - - - 3.68 - A IP24 - - - - 24 14 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - -
VENTO A50-1 S Pro (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 - 50 1155 - - - - - 4.83 - A IP24 - - - - 34 24 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - -
Vento Expert A50-1 W V.3
(I speed)
100-240 - 160 - yes - 0.035 - - - 50/60 800 I - - - - - - - IP24 - - - - - - - - - - 15 8 - -20...+40 41/47** - - - - - - - - - 2.4 - - - 4 2 - - - - - - - - 13 4 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2*** 5.0 - with open and closed front panel manual setting of 100% speed in a mobile application - -
Vento Expert A50-1 W V.3
(II speed)
100-240 - 160 - yes - 0.04 - - - 50/60 1300 II - - - - - - - IP24 - - - - - - - - - - 35 18 - -20...+40 41/47** - - - - - - - - - 1.23 - - - 10 5 - - - - - - - - 25 16 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2*** 6.0 - with open and closed front panel manual setting of 100% speed in a mobile application - -
Vento Expert A50-1 W V.3
(III speed)
100-240 - 160 - yes - 0.059 - - - 50/60 1900 III - - - - - - - IP24 - - - - - - - - - - 50 25 - -20...+40 41/47** - - - - - - - - - 1.22 - - - 14 7 - - - - - - - - 37 28 G3 (Option: G4; F7 PM2.5 > 70 %*) up to 95 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2*** 8.5 - with open and closed front panel manual setting of 100% speed in a mobile application - -
Freshbox E-100
Speed I
230 wall mounting - polymer-coated steel yes electric preheating - - 30 - 50/60 2200 I - - - 31 - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -15...+40 - - - 98 - - - - 10 8 - - G4 - - - - - 12 0.4 3.6 700 - - - 13 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100
Speed II
230 wall mounting - polymer-coated steel yes electric preheating - - 60 - 50/60 2200 II - - - 31 - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -15...+40 - - - 92 - - - - 10 17 - - G4 - - - - - 21 0.4 3.6 700 - - - 27 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
Freshbox E-100
Speed III
230 wall mounting - polymer-coated steel yes electric preheating - - 100 - 50/60 2200 III - - - 31 - - A - 1 - counter-flow polystyrene - - - - - 100 - - - -15...+40 - - - 89 - - - - 10 28 - - G4 - - - - - 45 0.4 3.6 700 - - - 39 - - - - LCD Filter replacement indication, Timer, Weekly schedule - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - -
VENTO A50 S (1 speed) 220-240 wall mounting 150 - - - 0.021 - 26 - 50 599 - - - - - 3.68 - A IP24 - - - - 24 14 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - -
VENTO A50 S (2 speed) 220-240 wall mounting 150 - - - 0.026 - 53 - 50 1155 - - - - - 4.83 - A IP24 - - - - 34 24 18 ≤ 90 - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - - - - - - Mechanical - - - - - - - - -
CIVIC EC LBE2 500 S14 230 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 580 - 50/60 1280 - - - Supply and exhaust 194±3% - - A - - 25 counter-flow polystyrene - - - - -25...+40 250 - - - - - - 40 mm mineral wool 75...94* 35 - 230 2800 - 161 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 1.7 20 1400 - - - - - - - - Sensor Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - -
CIVIC EC LBE2 500 S21 230 floor mounting - polymer-coated steel yes electric preheating, electric reheating - - 580 - 50/60 1280 - - - Supply and exhaust 194±3% - - A - 1 25 counter-flow polystyrene - - - - -25...+40 250 - - - - - - 40 mm mineral wool 75...94* 35 - 230 2800 - 161 - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - - - 1.7 20 1400 - - - - - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - - Heat recovery efficiency is specified in compliance with EN 13141-8 - - - -