Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Language: EN
Print version
Search results
Selected 1182 products
Mode VoltageStyleMountingDesignConnection diameterAir ductWidthHeightCasing materialEC motorOutdoor mountingSound-insulated casingHeatingFormMaterialDeviceCurrentPowerMaximum air flowSound pressure levelFrequencyRPMMaximum air capacityTypeWeight PowerMax. operating temperatureSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialElectric heater powerSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyTransported air temperature Electric heater currentCurrentConnected air duct diameterConnected air duct size FilterTransported air temperatureNumber of water coil rowsHumidity recovery efficiencySectional sizeInsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionMaximum air flowSFPWeightErPMaximum air flowBypassExtract filterSupply filterMotor IP ratingMax. power without electric heaterMax. unit powerMax. unit current without electric heaterMax. unit currentMax. unit power with electric heaterMax. unit current with electric heaterCurrentPreheater power consumptionRemote control panelFunctions*
Bravo Platinum 125 220-240 Platinum ceiling mounting, wall mounting axial 125 - - - - - - - - - - - 0.1 16 192 37* 50 2400 - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 53 0.3 - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan
Box-FI 60x35 6D 400 - Inline centrifugal - for rectangular air ducts 600 350 galvanized steel no no yes - - - - 1.47 - 3310 - 50 940 - Exhaust, Supply - 743 - - IPX4 3 46 - - - - - - - - - - - - - -20...+70 - - - - - - - - - 920 - 72 - - - - - IP44 - - - - - - - - - - -
BlauPlast FKH 204x60 - - - - - for rectangular air ducts - - - - - - - rectangular plastic holder - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 60х204 - - - - - - - - - - - - - - - - - - - - - - - - - -
Tower-H 560 4D 400 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - - - - 3.36 - 13560 - 50 1400 - Exhaust 81.4 1970 -25…+50 - IPX4 3 66 - - - - - - - - - - - - - - - - - - - - - - - 3767 - - 2018 - - - - IP54 - - - - - - - - - - -
Сentro-M 400 (50 Hz) 230 - Inline centrifugal 400 for round air ducts - - polymer-coated steel no no no - - - - 2.23 - 3090 - 50 1370 - Exhaust, Supply - 460 - - IPX4 1 61 - - - - - - - - - - - - - -40...+80 - - - - - - - - - 858 - 25.1 - - - - IP44 - - - - - - - - - - -
Сentro-M 400 (60 Hz) 230 - Inline centrifugal 400 for round air ducts - - polymer-coated steel no no no - - - - 3.05 - 3500 - 60 1585 - Exhaust, Supply - 673 - - IPX4 1 64 - - - - - - - - - - - - - -40…+55 - - - - - - - - - 972 - 25.1 - - - - IP44 - - - - - - - - - - -
Iso-RB 160 230 - Inline centrifugal 160 for round air ducts - - aluzinc no no yes - - - - 0.38 - 500 - 50 2670 - Exhaust, Supply - 86 - C IPX4 1 38 - - - - - - - - - - - - - -25...+55 - - - - - - - - - 139 - 17 2018 - - - - IP44 - - - - - - - - - - -
S-Vent 355х143-2.2-6D 400 - floor mounting centrifugal - for rectangular air ducts, for round air ducts - - polymer-coated steel no yes no - - - - 5.6 - - - 50 940 5090 Exhaust, Supply 49 2200 60 - IP54 - 71 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-I EC 50x25-1 230 - Inline centrifugal - for rectangular air ducts - - galvanized steel yes no yes - - - - 1.85 - - - 50/60 2500 1590 Exhaust, Supply 25.5 252 -25...+50 IPX4 1 34 - - - - - - - - - - - - - - - - - - - - - - - - - - 2018 442 - - - IP54 - - - - - - - - - - -
Box-D 125 (50 Hz) 230 - Inline centrifugal 125 for round air ducts - - galvanized steel no no no - - - - 0.26 - - - 50 2500 310 Exhaust 3.2 61 25 +50 C IPX4 1 48 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Box-D 125 (60 Hz) 230 - Inline centrifugal 125 for round air ducts - - galvanized steel no no no - - - - 0.36 - - - 60 2740 320 Exhaust 3.2 81 25 +50 C IPX4 1 49 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
KOMFORT EC S200-E S11 230 - wall mounting, floor mounting - - - - - polymer-coated steel yes - - - - - - - - 260 - 50/60 2050 - - - 130 - A - 1 24 counter-flow enthalpy - - - - - - - - 125 - - -25...+60 - - - 25 mm mineral wool 74–94 - - - - 72 - 45 2016, 2018 - - - G3 - - - - - - - 1.0 - - - -
KOMFORT Ultra L 250-E S12 white 230 - ceiling mounting, wall mounting, floor mounting - - for round air ducts - - - no no yes - - - - - - 250 - 50/60 2700 - Supply and exhaust - 148 - E - 1 28...47 cross-flow enthalpy - - - - - - - 0.78 125 - - -25...+40 - 27...45 - 20 mm mineral wool 52...73 - - - - 69 - - 2016 - - G4 G4 (option: F8 PM2.5 > 81 %) - - - - - - - - - - - -
Iso-B 250 230 - Inline centrifugal - for round air ducts - - galvanized steel no no yes - - - - 0.87 - - - 50 2420 1300 Exhaust, Supply 12.5 198 -25 +50 B IPX4 - 41 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Ducto Power Plus 150 min 220-240 White Inline axial 150 - - - - - - - - - - - 0.103 22 285 38* 50 2300 - Exhaust, Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 79 0.28 1.3 - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan
Ducto Power Plus 150 max 220-240 White Inline axial 150 - - - - - - - - - - - 0.109 25 375 41* 50 2600 - Exhaust, Supply - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 104 0.24 1.3 - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan
KOMFORT EC S 200 S14 230 - wall mounting, floor mounting - - - - - polymer-coated steel yes - - - - - - - - 250 - 50/60 2050 - - - 112 - A+ - 1 24 counter-flow polystyrene - - - - - - - - 125 - - -25...+40 - - - 25 mm mineral wool 83...98 - - - - 69 - 45 2016, 2018 - - G3 G3 - - - - - - - 0.9 - - - -
BLAUBOX ME 2500-18 Pro 400 - ceiling mounting, wall mounting, floor mounting centrifugal - for rectangular air ducts - - aluzinc no no - - - - - - - 2500 - 50 1000 - Supply - - - - - 3 45 - - 18000 - - - - -25...+40 26.0 - - 500х300 G4 - - - - 25 mm mineral wool - - - - - 695 - 62 2016, 2018 - - - - - 650 - 2.84 - 18650 28.84 - - - - -
Axis-Q 250 2Е
50 Hz
230 - wall mounting axial 250 for round air ducts - - polymer-coated steel no no no - - - - - - 1050 - 50 2400 - Exhaust, Supply - 80 - - IPX4 1 50 - - - - - - - - - - - - - -30...+60 - - - - - - - - - 292 - 4.0 - - - - - IP44 - - - - - - 0.4 - - - -
Axis-Q 250 2Е
60 Hz
230 - wall mounting axial 250 for round air ducts - - polymer-coated steel no no no - - - - - - 1150 - 60 2990 - Exhaust, Supply - 91 - - IPX4 1 51 - - - - - - - - - - - - - -30...+50 - - - - - - - - - 319 - 4.0 - - - - - IP44 - - - - - - 0.42 - - - -
Quatro Hi-Tech Chrome 150 220-240 Hi-Tech Chrome ceiling mounting, wall mounting axial 150 - - - - - - - - - - - 0.13 24 265 37* 50 2400 - Exhaust - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 74 0.33 - - - - - - - - - - - - - - - - - Sound pressure level measured in free space at a distance of 3 meters from the fan
KOMFORT EC DBW 550 R S21 230 - ceiling mounting - - - - - aluzinc - - - - - - - - - 620 - 50/60 3100 - Supply and exhaust - - - A - 1 30 counter-flow polystyrene - - - - - - - - 200 - - -25...+40 2 - - 20 mm mineral wool 78...90 - - - - 172 - 68 - - yes G4 G4 (Option: F7) - - 297 - 2.4 - - - - - - -
CIVIC EC LBE 500 S21 230 - floor mounting - - - - - polymer-coated steel yes - - electric preheating - - - - - 580 - 50/60 1280 - Supply and exhaust 193±3% - - A - 1 25 counter-flow polystyrene - - - - - -25...+40 - - 250 - - - - - - 40 mm mineral wool 75...94* 35 - 230 - 161 - - - - - G4 x 2 G4 + F8 (option: F8 C + H11) - - - 1.7 - - 7.8 - 1400 Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8
Tower-V 355 4Е (60 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - - - - 1.33 - 2976 - 60 1580 - Exhaust 26 304 -25…+50 - IPX4 1 52 - - - - - - - - - - - - - - - - - - - - - - - 827 - - - - - - - IP54 - - - - - - - - - - -
Tower-V 355 4Е (50 Hz) 230 - for roof centrifugal - for round air ducts - - polymer-coated steel no yes no - - - - 0.96 - 2480 - 50 1420 - Exhaust 26 219 -25…+50 - IPX4 1 51 - - - - - - - - - - - - - - - - - - - - - - - 689 - - 2018 - - - - IP54 - - - - - - - - - - -
Centro-MZ 150
50 Hz
230 - ceiling mounting, wall mounting centrifugal 150 for round air ducts - - galvanized steel no no no - - - - 0.29 - 455 - 50 2780 - Supply and exhaust 3.5 64 - B IPX4 - 44 - - - - - - - - - - - - - -25...+50 - - - - - - - - - 125 - - 2018 - - - - IP44 - - - - - - - - - - -
Centro-MZ 150
60 Hz
230 - ceiling mounting, wall mounting centrifugal 150 for round air ducts - - galvanized steel no no no - - - - 0.34 - 475 - 60 3216 - Supply and exhaust 3.5 78 - B IPX4 - 45 - - - - - - - - - - - - - -25...+50 - - - - - - - - - 132 - - 2018 - - - - IP44 - - - - - - - - - - -
KOMFORT Ultra EC L2 300-E S2 white 230 - ceiling mounting, wall mounting, floor mounting - 125 for round air ducts - - - yes no yes - - - - - - 300 - 50/60 2050 - Supply and exhaust - 165 - C - 1 33 cross-flow enthalpy - - - - - - - 1.3 - - - -25...+40 - 26...45 - - 51...73 - - - - 83 - 28 2016, 2018 - - G4 F8, G4 - - - - - - - - - - - -
VENTO V50-1 S (1 speed) 220-240 - wall mounting - - 164x164 - - - - - - - - - - 0.021 - 26 - 50 599 - - - 3.68 - A IP24 - - - - - 24 14 19 ≤ 90 - - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - Mechanical - -
VENTO V50-1 S (2 speed) 220-240 - wall mounting - - 164x164 - - - - - - - - - - 0.026 - 53 - 50 1155 - - - 4.83 - A IP24 - - - - - 34 24 19 ≤ 90 - - - - - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - - Mechanical - -
Box-F 100x50 8D 400 - Inline centrifugal - for rectangular air ducts 1000 500 galvanized steel no no no - - - - 4.1 - 7175 - 50 680 - Exhaust, Supply - 2000 -20...+40 - IPX4 3 59 - - - - - - - - - - - - - - - - - - - - - - - 1993 - 95.0 - - - - - IP44 - - - - - - - - - - -
CIVIC EC DB 1000 S21 230 - ceiling mounting - - - - - polymer-coated steel yes - - without heating - - - - - 1000 - 50/60 2070 - Supply and exhaust 267 - - A+ - 1 24 counter-flow polystyrene - - - - - -25...+40 - - 315 - - - - - - 25 mm, cellular synthetic rubber 83...93* 34 - 260 - 278 - - - - - G4 x 2 G4x2 + (option: F7 x 2) - - - 1.85 - - 1.85 - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection Heat recovery efficiency is specified in compliance with EN 13141-8
Pages