Blauberg KOMFORT ERV EC DB



- Description
- Modifications
- Downloads
- Designation key
- Accessories
FEATURES
Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. Reduction of load on air conditioning systems in a hot climate and heat loss in a cold climate due to heat and moisture recovery. Control of air exchange for creating comfortable indoor microclimate. Compatible with round Ø 100 or 150 mm air ducts. FANSThe unit is equipped with high-efficient external rotor EC motors used for air supply and exhaust. The KOMFORT ERV EC DB 100 S14, KOMFORT ERV EC DB 150 S14 and KOMFORT ERV EC DB 250 S14 units are equipped with a centrifugal impeller with forward curved blades and the KOMFORT ERV EC DB 350 S14 units – with backward curved blades. EC motors have the best power consumption to air flow ratio and meet the latest demands concerning energy saving and high-efficient ventilation. EC motors are featured with high performance, low noise level and totally controllable speed range. The impellers are dynamically balanced. |
The casing is made of polymer-coated steel panels, internally filled with foamed polyurethane layer 5-10 mm (depend on modification) for heat- and sound-insulation. The unit is equipped with a removable bottom panel for ease of maintenance. This service panel is used to access the filters and the heat exchanger for maintenance operations. The spigots are located at the sides of the unit and are equipped with rubber seals for airtight connection to the air ducts. The casing is equipped with fixing brackets to suspend the unit to the ceiling. |
|
|
||
HEAT RECOVERY
The integrated automatic freeze protection is used to prevent freezing of the heat exchanger in the cold season. The supply fan turns off according to the temperature sensor to get the heat exchanger warmed up with extract air. After that the supply fan turns on and the unit continues to run in the standard mode. AIR FILTRATIONTwo built-in G4 and F8 filters provide efficient supply air filtration. The G4 filter is used for extract air filtration. BYPASSThe units are equipped with a bypass for summer ventilation (air cooling by the cool air from outside). |
CONTROL AND AUTOMATION
Due to a low casing height the air handling units are a perfect solution for space-restricted installation above suspended ceilings. The unit mounting position must provide access for service maintenance. |
Modification name |
---|
KOMFORT ERV EC DB 100 S14 |
KOMFORT ERV EC DB 150 S14 |
KOMFORT ERV EC DB 250 S14 |
KOMFORT ERV EC DB 350 S14 |
Modification name | |
---|---|
KOMFORT ERV EC DB 100 S14 | |
KOMFORT ERV EC DB 150 S14 | |
KOMFORT ERV EC DB 250 S14 | |
KOMFORT ERV EC DB 350 S14 |
|
|
|
|
Series | Unit type | Motor type | Mounting type | Bypass | Rated air flow [m³/h] | Service side | Control |
KOMFORT | ERV: energy recovery ventilation | EC: electronically commutated motor | D: suspended mounting, horizontally directed spigots | B: integrated bypass | 100; 150; 250; 350 | R: right L: left |
S14: sensor control panel with LED indication |
KOMFORT ERV EC DB 100 S14 | KOMFORT ERV EC DB 150 S14 | KOMFORT ERV EC DB 250 S14 | KOMFORT ERV EC DB 350 S14 | ||
G4 panel filter | ![]() |
FP 200x191x20 G4 | FP 300x220x48 G4 | FP 300x220x48 G4 | FP 300x270x48 G4 |
F8 panel filter | ![]() |
FP 200x191x40 F8 | FP 300x220x48 F8 | FP 300x220x48 F8 | FP 300x270x48 F8 |
Humidity sensor | ![]() |
FS2 | FS2 | FS2 | FS2 |
CO2 sensor with indication | ![]() |
CD-1 | CD-1 | CD-1 | CD-1 |
CO2 sensor | ![]() |
CD-2 | CD-2 | CD-2 | CD-2 |
Humidity sensor | ![]() |
HR-S | HR-S | HR-S | HR-S |
Air damper | ![]() |
VKA 100 | VKA 100 | VKA 150 | VKA 150 |
Electric actuator | ![]() |
LF230 | LF230 | LF230 | LF230 |