Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Language: EN

Blauberg KOMFORT ERV EC DB

  • Description
  • Modifications
  • Downloads
  • Designation key
  • Accessories
Description
Description
FEATURES

Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. Reduction of load on air conditioning systems in a hot climate and heat loss in a cold climate due to heat and moisture recovery. Control of air exchange for creating comfortable indoor microclimate. Compatible with round Ø 100 or 150 mm air ducts.

FANS

The unit is equipped with high-efficient external rotor EC motors used for air supply and exhaust. The KOMFORT ERV EC DB 100 S14, KOMFORT ERV EC DB 150 S14 and KOMFORT ERV EC DB 250 S14 units are equipped with a centrifugal impeller with forward curved blades and the KOMFORT ERV EC DB 350 S14 units – with backward curved blades. EC motors have the best power consumption to air flow ratio and meet the latest demands concerning energy saving and high-efficient ventilation. EC motors are featured with high performance, low noise level and totally controllable speed range. The impellers are dynamically balanced.

 

DESIGN

The casing is made of polymer-coated steel panels, internally filled with foamed polyurethane layer 5-10 mm (depend on modification) for heat- and sound-insulation. The unit is equipped with a removable bottom panel for ease of maintenance. This service panel is used to access the filters and the heat exchanger for maintenance operations. The spigots are located at the sides of the unit and are equipped with rubber seals for airtight connection to the air ducts. The casing is equipped with fixing brackets to suspend the unit to the ceiling.

HEAT RECOVERY

The unit is equipped with an enthalpy plate cross-flow heat exchanger for energy (heat and humidity) recovery. Due to humidity recovery condensate is not generated in the enthalpy heat exchanger. The air flows are completely separated in the heat exchanger. Thus smells and contaminants are not transferred from the extract air to the supply air. Heat recovery is based on heat and/or humidity transfer through the heat exchanger plates. In the cold season supply air is heated in the heat exchanger by transferring the heat energy of warm and humid extract air to the cold fresh air. Heat recovery minimizes ventilation heat losses and heating costs respectively. In the warm season the heat exchanger performs reverse and intake air is cooled in the heat exchanger by the cool extract air. That reduces operation load on air conditioners and saves electricity.

FROST PROTECTION

The integrated automatic freeze protection is used to prevent freezing of the heat exchanger in the cold season. The supply fan turns off according to the temperature sensor to get the heat exchanger warmed up with extract air. After that the supply fan turns on and the unit continues to run in the standard mode.

AIR FILTRATION

Two built-in G4 and F8 filters provide efficient supply air filtration. The G4 filter is used for extract air filtration.

BYPASS

The units are equipped with a bypass for summer ventilation (air cooling by the cool air from outside).

  CONTROL AND AUTOMATION

The KOMFORT ERV EC DB S14 units have an integrated control system with a wall-mounted control panel S14 with a LED indication. The units are equipped with a USB connector (Type B) and can be connected to a PC for configuring the advanced settings in a special software. The standard delivery set includes a 10 m cable for connection of the unit to the control panel. S14 automation functions:

  • Unit On/Off.
  • Unit performance control (selection of Low, Medium or High speed).
  • Bypass damper opening and closing for summer ventilation.
  • Alarm indication.
  • Filter maintenance indication.
Additional functions of the S14 automation with installed software:
  • Fan speed adjustment from 0 to 100 %. Each speed is individually adjusted for the supply and the extract fans.
  • Operation control on feedback from the FS2 duct humidity sensor (to be ordered separately).
  • Unit operation setting according to the external control unit (to be ordered separately).
  • Temperature setting for freeze protection system activation.
  • Control and operation adjustment of the filter maintenance timer.
  • External relay control unit and humidity level control.
  • Software version upgrading.
MOUNTING

Due to a low casing height the air handling units are a perfect solution for space-restricted installation above suspended ceilings. The unit mounting position must provide access for service maintenance.

Modifications
Modification name
KOMFORT ERV EC DB 100 S14
KOMFORT ERV EC DB 150 S14
KOMFORT ERV EC DB 250 S14
KOMFORT ERV EC DB 350 S14
+
+
+
+
Documents archieve
Documents archieve
Select a document type
  • Catalogues
  • Technical documentation
  • Certificates
Name
KOMFORT ERV EC DB - user's manual (pdf 2.96Mb)
KOMFORT ERV EC DB - data sheet (pdf 1.17Mb)
KOMFORT ERV EC DB - image (png 231.04Kb)
S14 / S15 automation - software (zip 13.08Mb)
Designation key
Designation key
Series Unit type Motor type Mounting type Bypass Rated air flow [m³/h] Service side Control
KOMFORT ERV: energy recovery ventilation EC: electronically commutated motor D: suspended mounting, horizontally directed spigots B: integrated bypass 100; 150; 250; 350 R: right

L: left
S14: sensor control panel with LED indication
Accessories
Accessories
    KOMFORT ERV EC DB 100 S14 KOMFORT ERV EC DB 150 S14 KOMFORT ERV EC DB 250 S14 KOMFORT ERV EC DB 350 S14
G4 panel filter FP 200x191x20 G4 FP 300x220x48 G4 FP 300x220x48 G4 FP 300x270x48 G4
F8 panel filter FP 200x191x40 F8 FP 300x220x48 F8 FP 300x220x48 F8 FP 300x270x48 F8
Humidity sensor FS2 FS2 FS2 FS2
CO2 sensor with indication CD-1 CD-1 CD-1 CD-1
CO2 sensor CD-2 CD-2 CD-2 CD-2
Humidity sensor HR-S HR-S HR-S HR-S
Air damper VKA 100 VKA 100 VKA 150 VKA 150
Electric actuator LF230 LF230 LF230 LF230