Login
Not registered yet? Take advantages of registration:
Products saving in a binding to the projects
Online consultation from experts
Signup

Privacy policy
Language: EN

Equipment selection

x x м
м 3
м/час
Categories
All subcategories
  • Single-room reversible units Vento
  • Single-room units Freshbox
  • Single-room ventilation units Civic
Additionally
Show ×
Voltage
Functions
Remote control panel
Heating
Mounting
Hide filters
Fault
%
  • Selection method:
  • Air capacity:
  • Pressure:
Operating point
  • Air capacity: --
  • Pressure: ---
Print version
Search results
Selected 111 products
Mode VoltageMountingAir ductCasing materialEC motorHeatingCurrentMaximum air flowFrequencyRPMSpeedTypeWeight PowerSEC classIngress protection ratingPhaseSound pressure level at 3 mHeat exchanger typeHeat exchanger materialFan powerSound pressure level at 1 mSound pressure level at 3 mOutdoor sound pressure attenuationRegeneration efficiencyTransported air temperature Connected air duct diameterAir flow in ventilation modeAir flow in heat recovery modeTransported air temperatureOutdoor sound pressure attenuation in accordance with DIN EN 20140InsulationHeat recovery efficiencySound pressure level at a distance of 1 mVoltageMax. unit power without an electric heaterReheater power consumptionInsulation thiknessMaximum air flowSFPWeightExtract filterSupply filterAir flow in ventilation modeAir flow in heat recovery modeMax. power without electric heaterMax. unit current without electric heaterMax. unit current with electric heaterPreheater power consumptionSound pressure level at 1 m in accordance with ISO 3741:2004Sound pressure level at 3 m in accordance with ISO 3741:2004FilterHeat recovery efficiency in accordance with DIBt LÜ-A 20Remote control panelFunctionsIndoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8*****
Vento Ergo A50 S Pro1
(1 speed)
- - 150 - - - 0.024 21 50/60 610 I - - 4.5 - IP24 1 - - - - - - - - - - - 11 -20...+40 40 - - - 100-230 - - - 6 1.54 - - - - 3 - - - - 22 13 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - Filter replacement indication, Timer, Humidity sensor - - - - -
Vento Ergo A50 S Pro1
(2 speed)
- - 150 - - - 0.026 32 50/60 800 II - - 5 - IP24 1 - - - - - - - - - - - 16 -20...+40 40 - - - 100-230 - - - 9 1.12 - - - - 4 - - - - 29 20 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - Filter replacement indication, Timer, Humidity sensor - - - - -
Vento Ergo A50 S Pro1
(3 speed)
- - 150 - - - 0.039 50 50/60 1450 III - - 7 - IP24 1 - - - - - - - - - - - 25 -20...+40 40 - - - 100-230 - - - 14 1.01 - - - - 7 - - - - 32 23 G3 (Option: F8 PM2,5 > 99 %*) up to 88 - Filter replacement indication, Timer, Humidity sensor - - - - -
VENTO Ergo A50-1 S Pro
(1 speed)
100-230 wall mounting 150 - - - 0.024 21 50/60 610 - - - 4.5 A IP24 - - - - - 22 13 40 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - -
VENTO Ergo A50-1 S Pro
(2 speed)
100-230 wall mounting 150 - - - 0.026 32 50/60 800 - - - 5 A IP24 - - - - - 29 20 40 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - -
VENTO Ergo A50-1 S Pro
(3 speed)
100-230 wall mounting 150 - - - 0.039 50 50/60 1450 - - - 7 A IP24 - - - - - 32 23 40 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - -
Vento Ergo A85 S10 Pro1
(1 speed)
- - 150 - - - 0.034 36 50/60 1000 I - - 4.74 - IP24 1 - - - - - - - - - - - 18 -20...+40 40 - - - 100-230 - - - 10 0.95 - - - - 5 - - - - 29 19 G3 (Option: F8 PM2,5 > 99 %*) - - Filter replacement indication, Timer, Humidity sensor - - - - -
Vento Ergo A85 S10 Pro1
(2 speed)
- - 150 - - - 0.050 59 50/60 1500 II - - 6.56 - IP24 1 - - - - - - - - - - - 30 -20...+40 40 - - - 100-230 - - - 16 0.80 - - - - 8 - - - - 35 25 G3 (Option: F8 PM2,5 > 99 %*) - - Filter replacement indication, Timer, Humidity sensor - - - - -
Vento Ergo A85 S10 Pro1
(3 speed)
- - 150 - - - 0.071 85 50/60 2045 III - - 9.65 - IP24 1 - - - - - - - - - - - 43 -20...+40 40 - - - 100-230 - - - 24 0.82 - - - - 12 - - - - 44 34 G3 (Option: F8 PM2,5 > 99 %*) - - Filter replacement indication, Timer, Humidity sensor - - - - -
Freshbox E2-100 WiFi
Speed I
230 - - polymer-coated steel - electric preheating, electric reheating - 30 50/60 2200 I - - - A - 1 - counter-flow polystyrene - - - - - - 100 - - -15...+40 - - 98 - - - 350 10 8 - 31 G4 G4 - - 20 0.4 5.2 700 - 13 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox E2-100 WiFi
Speed II
230 - - polymer-coated steel - electric preheating, electric reheating - 44 50/60 2200 II - - - A - 1 - counter-flow polystyrene - - - - - - 100 - - -15...+40 - - 95 - - - 350 10 12 - 31 G4 G4 - - 23 0.4 5.2 700 - 20 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox E2-100 WiFi
Speed III
230 - - polymer-coated steel - electric preheating, electric reheating - 60 50/60 2200 III - - - A - 1 - counter-flow polystyrene - - - - - - 100 - - -15...+40 - - 92 - - - 350 10 17 - 31 G4 G4 - - 29 0.4 5.2 700 - 27 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox E2-100 WiFi
Speed IV
230 - - polymer-coated steel - electric preheating, electric reheating - 75 50/60 2200 IV - - - A - 1 - counter-flow polystyrene - - - - - - 100 - - -15...+40 - - 90 - - - 350 10 21 - 31 G4 G4 - - 37 0.4 5.2 700 - 33 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox E2-100 WiFi
Speed V
230 - - polymer-coated steel - electric preheating, electric reheating - 100 50/60 2200 V - - - A - 1 - counter-flow polystyrene - - - - - - 100 - - -15...+40 - - 89 - - - 350 10 28 - 31 G4 G4 - - 53 0.4 5.2 700 - 39 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
VENTO Expert A100-1 S10 W V.2 (Speed I) 100-240 - 160 - yes - 0.037 - 50/60 780 - - - - - IP24 - - - - 3.20 - - - - - - 18 9 -20 … +40 42 - - - - - - - - 1.28 - - - 5 3 - - - - 23 13 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2** Maximum air flow 82 m³/h At maximum speed -
VENTO Expert A100-1 S10 W V.2 (Speed II) 100-240 - 160 - yes - 0.046 - 50/60 1100 - - - - - IP24 - - - - 4.00 - - - - - - 30 15 -20 … +40 42 - - - - - - - - 0.96 - - - 8 4 - - - - 27 18 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2** Maximum air flow 82 m³/h At maximum speed -
VENTO Expert A100-1 S10 W V.2 (Speed III) 100-240 - 160 - yes - 0.071 - 50/60 1920 - - - - - IP24 - - - - 6.60 - - - - - - 58 29 -20 … +40 42 - - - - - - - - 0.82 - - - 16 8 - - - - 40 30 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2** Maximum air flow 82 m³/h At maximum speed -
VENTO Expert A100-1 S10 W V.2 (MAX) 100-240 - 160 - yes - 0.151 - 50/60 2940 - - - - - IP24 - - - - 18.00 - - - - - - 108 54 -20 … +40 42 - - - - - - - - 1.20 - - - 30 15 - - - - 51 42 G3 (Option: F8 PM2,5 > 99 %*) up to 87 Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection D1 S2** Maximum air flow 82 m³/h At maximum speed -
Freshbox 100 ERV WiFi
Speed I
110-240 - - polymer-coated steel - without heating - 30 50/60 2200 I - - - A - 1 - counter-flow enthalpy - - - - - - 100 - - -15...+40 - - 96 - - - - 10 8 - 31 G4 - - - 20 0.4 - - - 13 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox 100 ERV WiFi
Speed II
110-240 - - polymer-coated steel - without heating - 44 50/60 2200 II - - - A - 1 - counter-flow enthalpy - - - - - - 100 - - -15...+40 - - 94 - - - - 10 12 - 31 G4 - - - 23 0.4 - - - 20 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox 100 ERV WiFi
Speed III
110-240 - - polymer-coated steel - without heating - 60 50/60 2200 III - - - A - 1 - counter-flow enthalpy - - - - - - 100 - - -15...+40 - - 89 - - - - 10 17 - 31 G4 - - - 29 0.4 - - - 27 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox 100 ERV WiFi
Speed IV
110-240 - - polymer-coated steel - without heating - 75 50/60 2200 IV - - - A - 1 - counter-flow enthalpy - - - - - - 100 - - -15...+40 - - 85 - - - - 10 21 - 31 G4 - - - 37 0.4 - - - 33 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox 100 ERV WiFi
Speed V
110-240 - - polymer-coated steel - without heating - 100 50/60 2200 V - - - A - 1 - counter-flow enthalpy - - - - - - 100 - - -15...+40 - - 83 - - - - 10 28 - 31 G4 - - - 53 0.4 - - - 39 - - Sensor Wi-Fi Wi-Fi, Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
VENTO Ergo V50 S Pro (1 speed) 100-230 wall mounting 150x150 - - - 0.025 11 50/60 808 - - - 4.31 A IP24 - - - - - 28 19 19 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - -
VENTO Ergo V50 S Pro (2 speed) 100-230 wall mounting 150x150 - - - 0.029 24 50/60 1264 - - - 4.92 A IP24 - - - - - 33 24 19 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - -
VENTO Ergo V50 S Pro (3 speed) 100-230 wall mounting 150x150 - - - 0.035 35 50/60 1629 - - - 5.8 A IP24 - - - - - 39 29 19 ≤ 88 - - - - - - - - - 100-230 - - - - - - - - - - - - - - - - - - - Filter replacement indication, Timer, Humidity sensor - - - - -
Freshbox 100 ERV black
Speed I
110-240 wall mounting - polymer-coated steel yes without heating - 30 50/60 2200 I - 31 - A - 1 - counter-flow enthalpy - - - - - - 100 - - -15...+40 - - 96 - - - - 10 8 - - G4 - - - 12 0.4 - - - 13 - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox 100 ERV black
Speed II
110-240 wall mounting - polymer-coated steel yes without heating - 60 50/60 2200 II - 31 - A - 1 - counter-flow enthalpy - - - - - - 100 - - -15...+40 - - 89 - - - - 10 17 - - G4 - - - 21 0.4 - - - 27 - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
Freshbox 100 ERV black
Speed III
110-240 wall mounting - polymer-coated steel yes without heating - 100 50/60 2200 III - 31 - A - 1 - counter-flow enthalpy - - - - - - 100 - - -15...+40 - - 83 - - - - 10 28 - - G4 - - - 45 0.4 - - - 39 - - LCD Filter replacement indication, Timer, Weekly schedule - - Heat recovery efficiency is specified in compliance with EN 13141-8 -
VENTO A50-1 Pro (1 speed) 220-240 wall mounting 150 - - - 0.021 26 50 599 - - - 3.68 A IP24 - - - - - 24 14 18 ≤ 90 - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - Mechanical - - - - - -
VENTO A50-1 Pro (2 speed) 220-240 wall mounting 150 - - - 0.026 53 50 1155 - - - 4.83 A IP24 - - - - - 34 24 18 ≤ 90 - - - - - - - - - 220-240 - - - - - - - - - - - - - - - - - - Mechanical - - - - - -
CIVIC EC DBE 1000 S21 400 ceiling mounting - polymer-coated steel yes electric preheating - 1000 50/60 2070 - Supply and exhaust 271 - A+ - 3 24 counter-flow polystyrene - - - - - -25...+40 315 - - - - 25 mm, cellular synthetic rubber 83...93* 34 - 260 - - 278 - - G4 x 2 G4x2 + (option: F7 x 2) - - - 1.85 11.2 6300 - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - -
CIVIC EC DBE2 300 S21 230 ceiling mounting - polymer-coated steel yes electric preheating, electric reheating - 300 50/60 2150 - Supply and exhaust 80 - A - 1 23 counter-flow polystyrene - - - - - -25...+40 200 - - - - 25 mm, cellular synthetic rubber 76...88* 33 - 125 1400 - 83 - - G4 G4, F8 (option F8 C + H11) - - - 1.3 13.6 1050 - - - - Sensor, LCD Filter replacement indication, Timer, Weekly schedule, External sensor connection - - Heat recovery efficiency is specified in compliance with EN 13141-8 - -
Pages