Blauberg KOMFORT Roto EC D S21
- Description
- Modifications
- Downloads
- Designation key
- Accessories
FEATURES
Air handling units for efficient supply and exhaust ventilation in flats, houses, cottages and other buildings. Heat recovery is provided by the rotary heat exchanger and minimizes ventilation heat losses. Controllable air exchange for creating the best suitable indoor microclimate. Compatible with round Ø 160 and 200 mm air ducts. Additional spigot for kitchen hood air duct connection. DESIGNThe fan casing is made of galvanized steel, internally filled with mineral wool layer for heat and sound insulation. The spigots are located at the sides of the unit and are rubber sealed for airtight connection to the air ducts. KOMFORT Roto EC D(2) – model without electric heater. KOMFORT Roto EC D(2)E – model with electric heater. The insulation of KOMFORT Roto EC D(E) is 40 mm, for KOMFORT Roto EC D2(E) is 20 mm. Unit maintenance is performed from the bottom panel side. The distinctive feature of KOMFORT Roto EC D2(E) is a low casing profile. |
MOTORS
High-efficient external rotor EC motors and centrifugal impellers with forward curved blades are used for air supply and exhaust. EC motors have the best power consumption to air flow ratio and meet the latest demands concerning energy saving and high-efficient ventilation. EC motors are featured with high performance, low noise level and totally controllable speed range. Dynamically balanced impellers. MOUNTINGThe air handling unit is designed for suspension to a ceiling, wall mounting or mounting to a horizontal plane. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||
KOMFORT ROTO EC D(E) R (RIGHT SERVICE SIDE) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
KITCHEN HOOD
All the models are equipped with a fifth spigot for connection of the air duct from the kitchen hood. ROTARY HEAT EXCHANGERThe unit has a high-efficient rotary aluminium heat exchanger. The rotary heat exchanger is a short, rotating cylinder, filled with corrugated aluminium sheet layers. The air streams flow through them. The band layers of the heat exchanger first come in contact with the supply and then with extract air flows. Therefore the band is alternatively warmed up and cooled down and the extract air heat and humidity are transferred to the cold intake air. This way heat recovery reduces heat losses in the cold season and reduces operation load for air conditioner in the warm season. The advantages of the rotary heat exchanger as compared to the plate heat exchangers include no condensate generation, maintaining comfort air humidity and high freeze resistance. |
AIR FILTRATION
Two built-in filters with G4 and F7 filtration class provide efficient supply air filtration. Optionally, a H13 supply air filter may be used. The G4 filter is used for extract air filtration. HEATERThe KOMFORT Roto EC D(2)E units are equipped with the electric heater. If the necessary temperature level of the supply air cannot be achieved through heat recovery, the heater turns on automatically and heats the air supplied to the premise. The heaters incorporate protective measures securing the safe unit operation. CONTROL AND AUTOMATIONKOMFORT EC D… S21 units are equipped with an integrated automation system. The remote control panel is not included in the delivery set (purchased separately). The S21 controller allows integrating the unit into the Smart Home system or BMS (Building Management System). The unit can be controlled via the Blauberg AHU mobile application via Wi-Fi.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||
AUTOMATION FUNCTIONS | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Modification name | |
---|---|
KOMFORT Roto EC D 250 L/R S21 | |
KOMFORT Roto EC D 350 L/R S21 | |
KOMFORT Roto EC D 650 L/R S21 | |
KOMFORT Roto EC D2 250 L/R S21 | |
KOMFORT Roto EC D2 350 L/R S21 | |
KOMFORT Roto EC D2E 250 L/R S21 | |
KOMFORT Roto EC D2E 350 L/R S21 | |
KOMFORT Roto EC DE 250 L/R S21 | |
KOMFORT Roto EC DE 350 L/R S21 | |
KOMFORT Roto EC DE 650 L/R S21 |
|
|
|
|
|
|
|
|
|
|
Series | Unit type | Motor type | Mounting type | Modification | Heater type | Rated air flow [m³/h] | Service side | Control |
KOMFORT | Roto: rotary heat exchanger | EC: electronically commutated motor | D: suspended mounting, horizontally directed spigots | _: standard (insulation 40 mm) 2: low-profile (insulation 20 mm) |
_: no heater E: electric heater |
250; 350; 650 | L: left R: right |
S21 |
KOMFORT Roto EC D2(E) 250 L/R S21 |
KOMFORT Roto EC D(E) 250 L/R S21 |
KOMFORT Roto EC D2(E) 350 L/R S21 |
KOMFORT Roto EC D(E) 350 L/R S21 |
KOMFORT Roto EC D(E) 650 L/R S21 |
||
G4 panel filter | FP 280х180х48 G4 | FP 260х220х48 G4 | FP 372x180x48 G4 | FP 320x235x48 G4 | FP 378x295x48 G4 | |
F7 panel filter | FP 280х180х48 F7 | FP 260х220х48 F7 | FP 372x180x48 F7 | FP 320x235x48 F7 | FP 378x295x48 F7 | |
H13 panel filter | FP 280х180х48 H13 | FP 260х220х48 H13 | FP 372x180x48 H13 | FP 320x235x48 H13 | FP 378x295x48 H13 | |
Control panel | S22 | S22 | S22 | S22 | S22 | |
Wireless control panel | S22 Wi-Fi | S22 Wi-Fi | S22 Wi-Fi | S22 Wi-Fi | S22 Wi-Fi | |
LCD control panel | S25 | S25 | S25 | S25 | S25 | |
VOC sensor | DPWQ30600 | DPWQ30600 | DPWQ30600 | DPWQ30600 | DPWQ30600 | |
External CO2 sensor | DPWQ40200 | DPWQ40200 | DPWQ40200 | DPWQ40200 | DPWQ40200 | |
Humidity sensor | DPWC11200 | DPWС11200 | DPWC11200 | DPWС11200 | DPWС11200 | |
Humidity sensor | HR-S | HR-S | HR-S | HR-S | HR-S | |
Humidity sensor | FS2 | FS2 | FS2 | FS2 | FS2 | |
Kitchen hood | DAH 251-13 | DAH 251-13 | DAH 251-13 | DAH 251-13 | DAH 251-13 | |
Backdraft air damper | VRV 160 | VRV 160 | VRV 160 | VRV 160 | VRV 200 | |
Air damper | VKA 160 | VKA 160 | VKA 160 | VKA 160 | VKA 200 | |
Electric actuator | LF230 | LF230 | LF230 | LF230 | LF230 | |
Electric actuator | TF230 | TF230 | TF230 | TF230 | TF230 |