Mode | Voltage | Mounting | Air duct | Casing material | EC motor | Heating | Current | Power | Maximum air flow | Frequency | RPM | Speed | Type | Weight | Power | SEC class | Ingress protection rating | Phase | Sound pressure level at 3 m | Heat exchanger type | Heat exchanger material | Sound pressure level at 1 m | Sound pressure level at 3 m | Outdoor sound pressure attenuation | Regeneration efficiency | Transported air temperature | Connected air duct diameter | Air flow in ventilation mode | Air flow in heat recovery mode | Filter | Transported air temperature | Outdoor sound pressure attenuation in accordance with DIN EN 20140 | Regeneration efficiency in accordance with DIBt LÜ-A 20 | Insulation | Heat recovery efficiency | Sound pressure level at a distance of 1 m | Voltage | Max. unit power without an electric heater | Reheater power consumption | Insulation thikness | Maximum air flow | SFP | Weight | Extract filter | Supply filter | Air flow in ventilation mode | Air flow in heat recovery mode | Air flow in heat recovery mode | Air flow in heat recovery mode | Max. power without electric heater | Max. unit current without electric heater | Max. unit current with electric heater | Preheater power consumption | Max. current consumption with heater(s) | Sound pressure level at 1 m in accordance with ISO 3741:2004 | Sound pressure level at 3 m in accordance with ISO 3741:2004 | Filter | Heat recovery efficiency in accordance with DIBt LÜ-A 20 | Air flow in heat recovery mode | Air flow in heat recovery mode | Remote control panel | Functions | Indoor/outdoor airtightness classification of the complete unit in accordance with EN 13141-8 | Classification of air flow sensitivity to pressure difference variations in accordance with EN 13141-8 | Power | * | ** | *** | ** | Transported air temperature |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
VENTO Eco2 A50 S1 Pro (1 speed) | - | wall mounting | 160 | - | - | - | 0.030 | - | - | 50/60 | 1030 | - | - | - | 2.07 | A | IP24 | - | - | - | - | 22 | 13 | - | - | - | - | 15 | 15 | G3 (F8 PM2.5 > 99 %) | -20…+50 | 41 | ≤ 92 | - | - | - | 100-230 | - | - | - | - | - | - | - | - | 4 | 4 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor | Filter replacement indication, Timer | - | - | - | - | - | - | - | - |
VENTO Eco2 A50 S1 Pro (2 speed) | - | wall mounting | 160 | - | - | - | 0.049 | - | - | 50/60 | 1760 | - | - | - | 4.15 | A | IP24 | - | - | - | - | 29 | 20 | - | - | - | - | 30 | 30 | G3 (F8 PM2.5 > 99 %) | -20…+50 | 41 | ≤ 92 | - | - | - | 100-230 | - | - | - | - | - | - | - | - | 8 | 8 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor | Filter replacement indication, Timer | - | - | - | - | - | - | - | - |
VENTO Eco2 A50 S1 Pro (3 speed) | - | wall mounting | 160 | - | - | - | 0.098 | - | - | 50/60 | 2690 | - | - | - | 10.10 | A | IP24 | - | - | - | - | 32 | 23 | - | - | - | - | 50 | 50 | G3 (F8 PM2.5 > 99 %) | -20…+50 | 41 | ≤ 92 | - | - | - | 100-230 | - | - | - | - | - | - | - | - | 14 | 14 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor | Filter replacement indication, Timer | - | - | - | - | - | - | - | - |
Vento Expert Duo A30-1 S10 Pro (1 speed) |
100-240 | - | 160 | - | yes | - | 0.027 | - | 10 | 50/60 | 1600 | - | - | - | 2.00 | - | IP24 | - | - | - | - | - | - | - | - | -15…+40 | - | - | - | G3 | - | 42 | - | - | - | - | - | - | - | - | 3 | 0.72 | - | - | - | - | - | 60 | 16 | - | - | - | - | - | 33 | 24 | - | up to 85 | - | - | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | D2 | - | - | - | - | - | - | - |
Vento Expert Duo A30-1 S10 Pro (2 speed) |
100-240 | - | 160 | - | yes | - | 0.043 | - | 20 | 50/60 | 2200 | - | - | - | 3.70 | - | IP24 | - | - | - | - | - | - | - | - | -15…+40 | - | - | - | G3 | - | 42 | - | - | - | - | - | - | - | - | 6 | 0.67 | - | - | - | - | - | 60 | 16 | - | - | - | - | - | 40 | 31 | - | up to 85 | - | - | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | D2 | - | - | - | - | - | - | - |
Vento Expert Duo A30-1 S10 Pro (3 speed) |
100-240 | - | 160 | - | yes | - | 0.067 | - | 30 | 50/60 | 2500 | - | - | - | 6.40 | - | IP24 | - | - | - | - | - | - | - | - | -15…+40 | - | - | - | G3 | - | 42 | - | - | - | - | - | - | - | - | 8 | 0.77 | - | - | - | - | - | 60 | 16 | - | - | - | - | - | 43 | 34 | - | up to 85 | - | - | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | D2 | - | - | - | - | - | - | - |
VENTO Expert A50-1 Pro (1 speed) | 100-230 | wall mounting | 160 | - | - | - | 0.025 | - | - | 50/60 | 800 | - | - | - | 3.61 | A | IP24 | - | - | - | - | 20 | 11 | - | - | - | - | 15 | 8 | G3 (F8 PM2.5 > 99 %) | - | 42 | ≤ 93 | - | - | - | - | - | - | - | - | - | - | - | - | 4 | 2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | - | - | - | - | - | - | - | -20...+40 |
VENTO Expert A50-1 Pro (2 speed) | 100-230 | wall mounting | 160 | - | - | - | 0.03 | - | - | 50/60 | 1300 | - | - | - | 4.15 | A | IP24 | - | - | - | - | 27 | 18 | - | - | - | - | 30 | 15 | G3 (F8 PM2.5 > 99 %) | - | 42 | ≤ 93 | - | - | - | - | - | - | - | - | - | - | - | - | 8 | 4 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | - | - | - | - | - | - | - | -20...+40 |
VENTO Expert A50-1 Pro (3 speed) | 100-230 | wall mounting | 160 | - | - | - | 0.039 | - | - | 50/60 | 1900 | - | - | - | 5.20 | A | IP24 | - | - | - | - | 30 | 21 | - | - | - | - | 50 | 25 | G3 (F8 PM2.5 > 99 %) | - | 42 | ≤ 93 | - | - | - | - | - | - | - | - | - | - | - | - | 14 | 7 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor, External sensor connection | - | - | - | - | - | - | - | -20...+40 |
Vento Ergo A50 S10 Pro1 (1 speed) |
- | - | 150 | - | - | - | 0.024 | - | 21 | 50/60 | 610 | I | - | - | 4.5 | - | IP24 | 1 | - | - | - | - | - | - | - | - | - | - | - | - | -20...+40 | 40 | - | - | - | - | 100-230 | - | - | - | 6 | 1.54 | - | - | - | - | - | - | - | - | - | - | - | - | 22 | 13 | G3 (Option: F8 PM2,5 > 99 %*) | up to 88 | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
Vento Ergo A50 S10 Pro1 (2 speed) |
- | - | 150 | - | - | - | 0.026 | - | 32 | 50/60 | 800 | II | - | - | 5 | - | IP24 | 1 | - | - | - | - | - | - | - | - | - | - | - | - | -20 … +40 | 40 | - | - | - | - | 100-230 | - | - | - | 9 | 1.12 | - | - | - | - | - | - | - | - | - | - | - | - | 29 | 20 | G3 (Option: F8 PM2,5 > 99 %*) | up to 88 | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
Vento Ergo A50 S10 Pro1 (3 speed) |
- | - | 150 | - | - | - | 0.039 | - | 50 | 50/60 | 1450 | III | - | - | 7 | - | IP24 | 1 | - | - | - | - | - | - | - | - | - | - | - | - | -20 … +40 | 40 | - | - | - | - | 100-230 | - | - | - | 14 | 1.01 | - | - | - | - | - | - | - | - | - | - | - | - | 32 | 23 | G3 (Option: F8 PM2,5 > 99 %*) | up to 88 | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed I |
230 | - | - | polymer-coated steel | - | electric preheating | - | - | 30 | 50/60 | 2000 | I | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 85 | - | - | - | — | 30 | 8 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 10 | - | - | 650 | 4.0 | - | 12 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed II |
230 | - | - | polymer-coated steel | - | electric preheating | - | - | 60 | 50/60 | 2000 | II | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 81 | - | - | - | — | 30 | 17 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 15 | - | - | 650 | 4.0 | - | 22 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed III |
230 | - | - | polymer-coated steel | - | electric preheating | - | - | 90 | 50/60 | 2000 | III | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 75 | - | - | - | — | 30 | 25 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 25 | - | - | 650 | 4.0 | - | 30 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed IV |
230 | - | - | polymer-coated steel | - | electric preheating | - | - | 120 | 50/60 | 2000 | IV | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 68 | - | - | - | — | 30 | 33 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 44 | - | - | 650 | 4.0 | - | 36 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Freshbox E-200 ERV WiFi Speed V |
230 | - | - | polymer-coated steel | - | electric preheating | - | - | 200 | 50/60 | 2000 | V | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 66 | - | - | - | — | 30 | 56 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 134 | - | - | 650 | 4.0 | - | 45 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Vento Eco2 A50-4 S Pro (1 speed) | - | - | 160 | - | - | - | 0.033 | - | - | 50/60 | 915 | I | - | - | 2.37 | - | IP24 | - | - | - | - | - | - | - | - | - | - | 15 | - | - | -20(-30**) … +40 | 41 | - | - | - | - | 100-240 | - | - | - | - | 0.57 | - | - | - | 4 | - | - | - | - | - | - | - | - | 21 | 12 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 15 | 4 | Sensor | Filter replacement indication, Timer | D1 | S3*** | - | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - | - |
Vento Eco2 A50-4 S Pro (2 speed) | - | - | 160 | - | - | - | 0.047 | - | - | 50/60 | 1555 | II | - | - | 3.80 | - | IP24 | - | - | - | - | - | - | - | - | - | - | 30 | - | - | -20(-30**) … +40 | 41 | - | - | - | - | 100-240 | - | - | - | - | 0.46 | - | - | - | 8 | - | - | - | - | - | - | - | - | 27 | 18 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 30 | 8 | Sensor | Filter replacement indication, Timer | D1 | S3*** | - | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - | - |
Vento Eco2 A50-4 S Pro (3 speed) | - | - | 160 | - | - | - | 0.080 | - | - | 50/60 | 2330 | III | - | - | 7.61 | - | IP24 | - | - | - | - | - | - | - | - | - | - | 50 | - | - | -20(-30**) … +40 | 41 | - | - | - | - | 100-240 | - | - | - | - | 0.55 | - | - | - | 14 | - | - | - | - | - | - | - | - | 29 | 20 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | 50 | 14 | Sensor | Filter replacement indication, Timer | D1 | S3*** | - | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - | - |
Freshbox E1-100 WiFi Speed I |
230 | - | - | polymer-coated steel | - | electric reheating | - | - | 30 | 50/60 | 2200 | I | - | - | - | A | - | 1 | - | counter-flow | polystyrene | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 98 | - | - | - | 350 | 10 | 8 | - | 31 | G4 | G4 | - | - | - | - | 20 | 0.4 | 1.94 | - | - | - | 13 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | |
Freshbox E1-100 WiFi Speed II |
230 | - | - | polymer-coated steel | - | electric reheating | - | - | 44 | 50/60 | 2200 | II | - | - | - | A | - | 1 | - | counter-flow | polystyrene | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 95 | - | - | - | 350 | 10 | 12 | - | 31 | G4 | G4 | - | - | - | - | 23 | 0.4 | 1.94 | - | - | - | 20 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | |
Freshbox E1-100 WiFi Speed III |
230 | - | - | polymer-coated steel | - | electric reheating | - | - | 60 | 50/60 | 2200 | III | - | - | - | A | - | 1 | - | counter-flow | polystyrene | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 92 | - | - | - | 350 | 10 | 17 | - | 31 | G4 | G4 | - | - | - | - | 29 | 0.4 | 1.94 | - | - | - | 27 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | |
Freshbox E1-100 WiFi Speed IV |
230 | - | - | polymer-coated steel | - | electric reheating | - | - | 75 | 50/60 | 2200 | IV | - | - | - | A | - | 1 | - | counter-flow | polystyrene | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 90 | - | - | - | 350 | 10 | 21 | - | 31 | G4 | G4 | - | - | - | - | 37 | 0.4 | 1.94 | - | - | - | 33 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | |
Freshbox E1-100 WiFi Speed V |
230 | - | - | polymer-coated steel | - | electric reheating | - | - | 100 | 50/60 | 2200 | V | - | - | - | A | - | 1 | - | counter-flow | polystyrene | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 89 | - | - | - | 350 | 10 | 28 | - | 31 | G4 | G4 | - | - | - | - | 53 | 0.4 | 1.94 | - | - | - | 39 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | |
VENTO Ergo A50-1 Pro (1 speed) |
- | wall mounting | 150 | - | - | - | 0.024 | - | 21 | 50/60 | 610 | - | - | - | 4.5 | A | IP24 | - | - | - | - | 22 | 13 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo A50-1 Pro (2 speed) |
- | wall mounting | 150 | - | - | - | 0.026 | - | 32 | 50/60 | 800 | - | - | - | 5 | A | IP24 | - | - | - | - | 29 | 20 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo A50-1 Pro (3 speed) |
- | wall mounting | 150 | - | - | - | 0.039 | - | 50 | 50/60 | 1450 | - | - | - | 7 | A | IP24 | - | - | - | - | 32 | 23 | 40 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
CIVIC EC DBE2 500 S21 | 230 | ceiling mounting | - | polymer-coated steel | yes | electric preheating, electric reheating | - | - | 510 | 50/60 | 1700 | - | Supply and exhaust | 130 | - | A | - | 1 | 24 | counter-flow | polystyrene | - | - | - | - | -25...+40 | 250 | - | - | - | - | - | - | 25 mm, cellular synthetic rubber | 74...86* | 34 | - | 170 | 1750 | - | 142 | - | - | G4 | G4, F8 (option F8 C + H11) | - | - | - | - | - | 1.7 | 18.2 | 1750 | - | - | - | - | - | - | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
Vento Expert A30 S10 W V.2(1 speed) | 100-240 | wall mounting | 100 | - | yes | - | 0.027 | - | 10 | 50/60 | 1600 | - | - | - | 1.80 | - | IP24 | - | 21 | - | - | - | - | - | - | - | - | - | 5 | G3 | -15…+40 | 42 | - | - | - | 30 | - | - | - | - | 3 | 1.30 | - | - | - | - | 1 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor | D1 | - | - | - | - | - | - | - |
Vento Expert A30 S10 W V.2(2 speed) | 100-240 | wall mounting | 100 | - | yes | - | 0.037 | - | 20 | 50/60 | 2200 | - | - | - | 3 | - | IP24 | - | 28 | - | - | - | - | - | - | - | - | - | 10 | G3 | -15…+40 | 42 | - | - | - | 37 | - | - | - | - | 6 | 1.08 | - | - | - | - | 3 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor | D1 | - | - | - | - | - | - | - |
Vento Expert A30 S10 W V.2(3 speed) | 100-240 | wall mounting | 100 | - | yes | - | 0.051 | - | 30 | 50/60 | 2500 | - | - | - | 4.40 | - | IP24 | - | 31 | - | - | - | - | - | - | - | - | - | 15 | G3 | -15…+40 | 42 | - | - | - | 40 | - | - | - | - | 8 | 1.06 | - | - | - | - | 4 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor | D1 | - | - | - | - | - | - | - |
VENTO Ergo V50 Pro (1 speed) | 100-230 | wall mounting | 150x150 | - | - | - | 0.025 | - | 11 | 50/60 | 808 | - | - | - | 4.31 | A | IP24 | - | - | - | - | 28 | 19 | 19 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo V50 Pro (2 speed) | 100-230 | wall mounting | 150x150 | - | - | - | 0.029 | - | 24 | 50/60 | 1264 | - | - | - | 4.92 | A | IP24 | - | - | - | - | 33 | 24 | 19 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
VENTO Ergo V50 Pro (3 speed) | 100-230 | wall mounting | 150x150 | - | - | - | 0.035 | - | 35 | 50/60 | 1629 | - | - | - | 5.8 | A | IP24 | - | - | - | - | 39 | 29 | 19 | ≤ 88 | - | - | - | - | - | - | - | - | - | - | - | 100-230 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Filter replacement indication, Timer, Humidity sensor | - | - | - | - | - | - | - | - |
Vento Expert A50-1 S W V.3(I speed) | 100-240 | - | 160 | - | yes | - | 0.035 | - | - | 50/60 | 800 | I | - | - | - | - | IP24 | - | - | - | - | - | - | - | - | - | - | 15 | 8 | - | -20...+40 | 41/47** | - | - | - | - | - | - | - | - | - | 2.4 | - | - | - | 4 | 2 | - | - | - | - | - | - | - | 13 | 4 | G3 (Option: G4; F7 PM2.5 > 70 %*) | up to 95 | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection | D1 | S2*** | 5.0 | Maximum air flow 40 m³/h | with open and closed front panel | manual setting of 100% speed in a mobile application | - | - |
Vento Expert A50-1 S W V.3(II speed) | 100-240 | - | 160 | - | yes | - | 0.04 | - | - | 50/60 | 1300 | II | - | - | - | - | IP24 | - | - | - | - | - | - | - | - | - | - | 35 | 18 | - | -20...+40 | 41/47** | - | - | - | - | - | - | - | - | - | 1.23 | - | - | - | 10 | 5 | - | - | - | - | - | - | - | 25 | 16 | G3 (Option: G4; F7 PM2.5 > 70 %*) | up to 95 | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection | D1 | S2*** | 6.0 | Maximum air flow 40 m³/h | with open and closed front panel | manual setting of 100% speed in a mobile application | - | - |
Vento Expert A50-1 S W V.3(III speed) | 100-240 | - | 160 | - | yes | - | 0.059 | - | - | 50/60 | 1900 | III | - | - | - | - | IP24 | - | - | - | - | - | - | - | - | - | - | 50 | 25 | - | -20...+40 | 41/47** | - | - | - | - | - | - | - | - | - | 1.22 | - | - | - | 14 | 7 | - | - | - | - | - | - | - | 37 | 28 | G3 (Option: G4; F7 PM2.5 > 70 %*) | up to 95 | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule, Humidity sensor, External sensor connection | D1 | S2*** | 8.5 | Maximum air flow 40 m³/h | with open and closed front panel | manual setting of 100% speed in a mobile application | - | - |
Freshbox E-100 ERV Speed I |
230 | wall mounting | - | polymer-coated steel | yes | electric preheating | - | - | 30 | 50/60 | 2200 | I | - | 31 | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 90 | - | - | - | - | 10 | 8 | - | - | G4 | - | - | - | - | - | 12 | 0.4 | 3.6 | 700 | - | - | 13 | - | - | - | - | LCD | Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | |
Freshbox E-100 ERV Speed II |
230 | wall mounting | - | polymer-coated steel | yes | electric preheating | - | - | 60 | 50/60 | 2200 | II | - | 31 | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 86 | - | - | - | - | 10 | 17 | - | - | G4 | - | - | - | - | - | 21 | 0.4 | 3.6 | 700 | - | - | 27 | - | - | - | - | LCD | Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | |
Freshbox E-100 ERV Speed III |
230 | wall mounting | - | polymer-coated steel | yes | electric preheating | - | - | 100 | 50/60 | 2200 | III | - | 31 | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 83 | - | - | - | - | 10 | 28 | - | - | G4 | - | - | - | - | - | 45 | 0.4 | 3.6 | 700 | - | - | 39 | - | - | - | - | LCD | Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | |
VENTO A50-1 S (1 speed) | 220-240 | wall mounting | 150 | - | - | - | 0.021 | - | 26 | 50 | 599 | - | - | - | 3.68 | A | IP24 | - | - | - | - | 24 | 14 | 18 | ≤ 90 | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - | - | - | - |
VENTO A50-1 S (2 speed) | 220-240 | wall mounting | 150 | - | - | - | 0.026 | - | 53 | 50 | 1155 | - | - | - | 4.83 | A | IP24 | - | - | - | - | 34 | 24 | 18 | ≤ 90 | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - | - | - | - |
CIVIC EC LBE 1200 S21 | 400 | floor mounting | - | polymer-coated steel | yes | electric preheating | - | - | 1240 | 50/60 | 3630 | - | Supply and exhaust | 398 | - | A+ | - | 3 | 24 | counter-flow | polystyrene | - | - | - | - | -25...+40 | 400 | - | - | - | - | - | - | 40 mm mineral wool | 84...96* | 34 | - | 350 | - | - | 344 | - | - | G4 | G4 + (option: F7) | - | - | - | - | - | 1.6 | 9.6 | 6300 | - | - | - | - | - | - | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
CIVIC EC DB 300 S21 | 230 | ceiling mounting | - | polymer-coated steel | yes | without heating | - | - | 300 | 50/60 | 2150 | - | Supply and exhaust | 78 | - | A | - | 1 | 23 | counter-flow | polystyrene | - | - | - | - | -25...+40 | 200 | - | - | - | - | - | - | 25 mm, cellular synthetic rubber | 76...88* | 33 | - | 125 | - | - | 83 | - | - | G4 | G4, F8 (option F8 C + H11) | - | - | - | - | - | 1.3 | 1.3 | - | - | - | - | - | - | - | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
VENTO V50-1 S (1 speed) | 220-240 | wall mounting | 164x164 | - | - | - | 0.021 | - | 26 | 50 | 599 | - | - | - | 3.68 | A | IP24 | - | - | - | - | 24 | 14 | 19 | ≤ 90 | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - | - | - | - |
VENTO V50-1 S (2 speed) | 220-240 | wall mounting | 164x164 | - | - | - | 0.026 | - | 53 | 50 | 1155 | - | - | - | 4.83 | A | IP24 | - | - | - | - | 34 | 24 | 19 | ≤ 90 | - | - | - | - | - | - | - | - | - | - | - | 220-240 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Mechanical | - | - | - | - | - | - | - | - | - |
CIVIC EC LBE 300-E S14 | 230 | floor mounting | - | polymer-coated steel | yes | electric preheating | - | - | 320 | 50/60 | 2150 | - | Supply and exhaust | 137±3% | - | A | - | 1 | 21 | counter-flow | enthalpy | - | - | - | - | -25...+40 | 200 | - | - | - | - | - | - | 40 mm mineral wool | 73...89* | 31 | - | 125 | - | - | 89 | - | - | G4 x 2 | G4 + F8 (option: F8 C + H11) | - | - | - | - | - | 0.9 | 7 | 1400 | - | - | - | - | - | - | - | Sensor | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
CIVIC EC LBE 300-E S21 | 230 | floor mounting | - | polymer-coated steel | yes | electric preheating | - | - | 320 | 50/60 | 2150 | - | Supply and exhaust | 137±3% | - | A | - | 1 | 21 | counter-flow | enthalpy | - | - | - | - | -25...+40 | 200 | - | - | - | - | - | - | 40 mm mineral wool | 73...89* | 31 | - | 125 | - | - | 89 | - | - | G4 x 2 | G4 + F8 (option: F8 C + H11) | - | - | - | - | - | 0.9 | 7 | 1400 | - | - | - | - | - | - | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
VENTO Solar V60 S Pro (1 speed) | - | wall mounting | - | - | - | - | 0.018 | 2.8 | 35 | - | 1150 | - | - | - | - | A+ | IP24 | - | 24 | - | - | - | - | 19 | up to 88 | - | - | - | - | - | - | - | - | - | - | 34 | 12 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
VENTO Solar V60 S Pro (2 speed) | - | wall mounting | - | - | - | - | 0.018 | 2.8 | 35 | - | 1150 | - | - | - | - | A+ | IP24 | - | 24 | - | - | - | - | 19 | up to 88 | - | - | - | - | - | - | - | - | - | - | 34 | 12 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Vento Eco A50-4 S11 Pro (1 speed) | 100-240 | wall mounting | 160 | - | yes | - | 0.017 | - | - | 50/60 | 915 | - | - | - | 1.00 | - | IP24 | - | - | - | - | - | - | - | - | - | - | 15 | 8 | - | 20(-30**) … +40 | 41 | - | - | - | - | - | - | - | - | - | 0.48 | - | - | - | 4 | 2 | - | - | - | - | - | - | - | 21 | 12 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | - | - | Sensor | Filter replacement indication, Timer | D1 | S3*** | - | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - | - |
Vento Eco A50-4 S11 Pro (2 speed) | 100-240 | wall mounting | 160 | - | yes | - | 0.025 | - | - | 50/60 | 1555 | - | - | - | 2.10 | - | IP24 | - | - | - | - | - | - | - | - | - | - | 30 | 15 | - | 20(-30**) … +40 | 41 | - | - | - | - | - | - | - | - | - | 0.50 | - | - | - | 8 | 4 | - | - | - | - | - | - | - | 27 | 18 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | - | - | Sensor | Filter replacement indication, Timer | D1 | S3*** | - | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - | - |
Vento Eco A50-4 S11 Pro (3 speed) | 100-240 | wall mounting | 160 | - | yes | - | 0.041 | - | - | 50/60 | 2330 | - | - | - | 4.30 | - | IP24 | - | - | - | - | - | - | - | - | - | - | 50 | 25 | - | 20(-30**) … +40 | 41 | - | - | - | - | - | - | - | - | - | 0.62 | - | - | - | 14 | 7 | - | - | - | - | - | - | - | 29 | 20 | G3 (Option: F8 PM2,5 > 99 %*) | up to 92 | - | - | Sensor | Filter replacement indication, Timer | D1 | S3*** | - | Maximum air flow 40 m³/h | With ZL1 Vento 160/100 cartridge and AH-8 outer hood applied | At III speed | - | - |
VENTO ECO A50 S1(S9) Pro (1 speed) | - | wall mounting | 160 | - | - | - | 0.018 | - | - | 50/60 | 1030 | - | - | - | 0.89 | A | IP24 | - | - | - | - | 22 | 13 | - | - | - | - | 15 | 8 | G3 (F8 PM2.5 > 99 %) | -20…+50 | 41 | ≤ 92 | - | - | - | 100-230 | - | - | - | - | - | - | - | - | 4 | 2 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor | Filter replacement indication, Timer | - | - | - | - | - | - | - | - |
VENTO ECO A50 S1(S9) Pro (2 speed) | - | wall mounting | 160 | - | - | - | 0,032 | - | - | 50/60 | 1760 | - | - | - | 2.32 | A | IP24 | - | - | - | - | 29 | 20 | - | - | - | - | 30 | 15 | G3 (F8 PM2.5 > 99 %) | -20…+50 | 41 | ≤ 92 | - | - | - | 100-230 | - | - | - | - | - | - | - | - | 8 | 4 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor | Filter replacement indication, Timer | - | - | - | - | - | - | - | - |
VENTO ECO A50 S1(S9) Pro (3 speed) | - | wall mounting | 160 | - | - | - | 0.060 | - | - | 50/60 | 2690 | - | - | - | 5.39 | A | IP24 | - | - | - | - | 32 | 23 | - | - | - | - | 50 | 25 | G3 (F8 PM2.5 > 99 %) | -20…+50 | 41 | ≤ 92 | - | - | - | 100-230 | - | - | - | - | - | - | - | - | 14 | 7 | - | - | - | - | - | - | - | - | - | - | - | - | - | Sensor | Filter replacement indication, Timer | - | - | - | - | - | - | - | - |
CIVIC EC LB 1200 S21 | 400 | floor mounting | - | polymer-coated steel | yes | - | - | - | 1240 | 50/60 | 3630 | - | Supply and exhaust | 394 | - | A+ | - | 3 | 24 | counter-flow | polystyrene | - | - | - | - | -25...+40 | 400 | - | - | - | - | - | - | 40 mm mineral wool | 84...96* | 34 | - | 350 | - | - | 344 | - | - | G4 | G4 + (option: F7) | - | - | - | - | - | 1.6 | 1.6 | - | - | - | - | - | - | - | - | Sensor, LCD | Filter replacement indication, Timer, Weekly schedule, External sensor connection | - | - | - | Heat recovery efficiency is specified in compliance with EN 13141-8 | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed I |
230 | - | - | polymer-coated steel | - | electric preheating, electric reheating | - | - | 30 | 50/60 | 2000 | I | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 85 | - | - | - | 700 | 30 | 8 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 10 | - | - | 650 | 7.2 | - | 12 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed II |
230 | - | - | polymer-coated steel | - | electric preheating, electric reheating | - | - | 60 | 50/60 | 2000 | II | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 81 | - | - | - | 700 | 30 | 17 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 15 | - | - | 650 | 7.2 | - | 22 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed III |
230 | - | - | polymer-coated steel | - | electric preheating, electric reheating | - | - | 90 | 50/60 | 2000 | III | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 75 | - | - | - | 700 | 30 | 25 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 25 | - | - | 650 | 7.2 | - | 30 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed IV |
230 | - | - | polymer-coated steel | - | electric preheating, electric reheating | - | - | 120 | 50/60 | 2000 | IV | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 68 | - | - | - | 700 | 30 | 33 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 44 | - | - | 650 | 7.2 | - | 36 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
Freshbox E2-200 ERV WiFi Speed V |
230 | - | - | polymer-coated steel | - | electric preheating, electric reheating | - | - | 200 | 50/60 | 2000 | V | - | - | - | A | - | 1 | - | counter-flow | enthalpy | - | - | - | - | - | 100 | - | - | - | -15...+40 | - | - | - | 66 | - | - | - | 700 | 30 | 56 | - | 55 | G4 | G4 + F7 (Option: H13) | - | - | - | - | 134 | - | - | 650 | 7.2 | - | 45 | - | - | - | - | Sensor Wi-Fi | Wi-Fi, Filter replacement indication, Timer, Weekly schedule | - | - | - | - | - | - | - | - |
VENTO Expert A50-1 W (1 speed) | 100-230 | wall mounting | 160 | - | - | - | 0.035 | - | - | 50/60 | 800 | - | - | - | 4.45 | A | IP24 | - | - | - | - | 20 | 11 | - | - | - | - | 15 | 8 | G3 (F8 PM2,5 > 99 %) | - | 42 | ≤ 93 | - | - | - | - | - | - | - | - | - | - | - | - | 4 | 2 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection | - | - | - | - | - | - | - | -20...+40 |
VENTO Expert A50-1 W (2 speed) | 100-230 | wall mounting | 160 | - | - | - | 0.04 | - | - | 50/60 | 1300 | - | - | - | 5.08 | A | IP24 | - | - | - | - | 27 | 18 | - | - | - | - | 30 | 15 | G3 (F8 PM2.5 > 99 %) | - | 42 | ≤ 93 | - | - | - | - | - | - | - | - | - | - | - | - | 8 | 4 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection | - | - | - | - | - | - | - | -20...+40 |
VENTO Expert A50-1 W (3 speed) | 100-230 | wall mounting | 160 | - | - | - | 0.059 | - | - | 50/60 | 1900 | - | - | - | 7.06 | A | IP24 | - | - | - | - | 30 | 21 | - | - | - | - | 50 | 25 | G3 (F8 PM2.5 > 99 %) | - | 42 | ≤ 93 | - | - | - | - | - | - | - | - | - | - | - | - | 14 | 7 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Wi-Fi, Filter replacement indication, Timer, Humidity sensor, External sensor connection | - | - | - | - | - | - | - | -20...+40 |